Show simple item record

dc.contributor.advisorLubis, Bugis Mardina
dc.contributor.advisorSianturi, Pertin
dc.contributor.authorHumairah, Siti
dc.date.accessioned2025-01-22T03:41:37Z
dc.date.available2025-01-22T03:41:37Z
dc.date.issued2024
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/100440
dc.description.abstractBackgound: Acute respiratory insufficiency often occurs in neonates requiring mechanical ventilation in the NICU as a countermeasure by intubation. Prolonged intubation can lead to complications such as ventilator-associated pneumonia, airway trauma and bronchopulmonary dysplasia (BPD). These complications often arise due to difficulties in determining the right time to extubate neonates. Further evaluation is needed on the accuracy of the oxygen index as a parameter of extubation in neonates Method: We conduct observational study with diagnostic test to evaluate the accuration of oxygen index with extubation success in neonates aged 0-28 days using mechanical ventilation on Haji Adam Malik Central General Hospital, Medan, North Sumatera, Indonesia during September 2021-2022. Result: This study was followed by 50 neonates using mechanical ventilation who were treated in the neonatal intensive care unit (NICU), 30 boys (60%) and 20 girls (40%). Seven neonates (14%) experienced failed extubation and 43 neonates (86%) were successfully extubated. The results of the oxygen index examination showed an average of 1.62 (SD = 1.41). ROC curve in predicting the success of extubation were 84% with a p value = 0.004 and 95% CI 65.1% - 100% with a cut off of 1.1. Conclusion: There was a significant relationship between the oxygen index and extubation success in neonates using mechanical ventilationen_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectoxygen indexen_US
dc.subjectneonatesen_US
dc.subjectintubationen_US
dc.subjectmechanical ventilationen_US
dc.subjectextubationen_US
dc.titleAkurasi Indeks Oksigen terhadap Keberhasilan Ekstubasi pada Neonatus yang Menggunakan Ventilasi Mekaniken_US
dc.title.alternativeThe Accuracy of Oxygen Index in Relation to Successful Extubation in Neonates Undergoing Mechanical Ventilationen_US
dc.typeThesisen_US
dc.identifier.nimNIM197103014
dc.identifier.nidnNIDN0003107002
dc.identifier.kodeprodiKODEPRODI11711#Ilmu Kesehatan Anak
dc.description.pages79 Pagesen_US
dc.description.typeTesis Magisteren_US
dc.subject.sdgsSDGs 3. Good Health And Well Beingen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record