Show simple item record

dc.contributor.advisorBarus, Diana Alemin
dc.contributor.authorFajar, Aisah
dc.date.accessioned2025-02-20T08:28:45Z
dc.date.available2025-02-20T08:28:45Z
dc.date.issued2024
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/101529
dc.description.abstractOne of the radiation protection programs has been carried out by measuring the exposure to scattering radiation around the cesium-137 room at BPFK Medan. Measurements were made in five rooms using a babyline surveymeter. The measurements were carried out to obtain the value of radiation exposure rate in the cesium-137 room, the value of radiation exposure rate in the room around the cesium-137 room, and finally to obtain the effectiveness value of radiation shielding in BPFK. Measurements were made by observing the point to be measured, measuring and documenting. From the measurements taken, the radiation exposure rate value was obtained after passing through the shield. In the operator's room, the exposure rate is 0.00014 mSv/year; in the inventory room, 0.00007 mSv/year; in the product test lab room, 0.00016 mSv/year; in the parking lot, 0.00009 mSv/year; in the large hall meeting room, 0.00011 mSv/year. From the measurements inside and outside the cesium-137 room, the percentage of radiation shielding effectiveness can be calculated. In the operator's room the effectiveness of the shield is 94.40%; in the inventory room the effectiveness of the shield is 98.44%; in the product test lab room the effectiveness is 98.44%; in the parking lot the effectiveness is obtained at 98.8%. Based on Perka BAPETEN No.4 Year 2013, the data shows that the value of radiation exposure around the cesium-137 room at BPFK Medan is still within safe limits.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectCesium-137en_US
dc.subjectProtectionen_US
dc.subjectShielding Effectivenessen_US
dc.subjectExposure Rateen_US
dc.titlePengukuran Laju Paparan Radiasi dan Efektivitas Perisai Radiasi Pada Ruang Cs-137 di BPFK Medanen_US
dc.title.alternativeMeasurement of Radiation Exposure Rate and Effectiveness of Radiation Shielding in Cs-137 Room in BPFK Medanen_US
dc.typeThesisen_US
dc.identifier.nimNIM200801054
dc.identifier.nidnNIDN0029076603
dc.identifier.kodeprodiKODEPRODI45201#Fisika
dc.description.pages55 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US
dc.subject.sdgsSDGs 9. Industry Innovation And Infrastructureen_US