Show simple item record

dc.contributor.advisorHandana, Muhammad Agung Putra
dc.contributor.authorNainggolan, Margharetha Yolanda
dc.date.accessioned2025-04-14T01:15:08Z
dc.date.available2025-04-14T01:15:08Z
dc.date.issued2025
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/102905
dc.description.abstractIndonesia is located at the confluence of four tectonic plates and vulnerable to seismic hazards. This may result in structural failures by improper planning, use an old seismic design code, or the absence of seismic hazard planning. Existing buildings with/without old codes, must go thru seismic evaluations based on ASCE 41-17 to determine the building performance, redundancy and rehabilitation when necessary. Teladan Stadium Tower as the case study is aims to determine the its structural performance as an ODCB during an earthquake in accordance with the applicable design code. The type of research conducted is a case study of an existing building located at Jalan Stadion, Teladan Barat, Medan. The seismic evaluation based on ASCE 41-17 which starts by determining the building’s general information. Building modelling is using MIDAS GEN 2024. The analysis was conducted with Tier 1 Screening and Tier 2 Deficiency-Based Evaluation. The Tier 1 analysis results show the soft story, mass, column axial stress, slenderness of diagonals, and compact members were non-compliant (NC). The column axial stress value exceeds 0.3Fy by 199.5079 MPa > 72 MPa due to overturning. The bracing diagonal slenderness ratio is 217.3913. The bracing thickness to width ratio exceeds the AISC 341 compact section limitation by 12.5 > 11.6905. Meanwhile, the Tier 2 analysis results show that the axial stress of column H does not meet the cross-section criteria of 1.26 > 1, but meets the requirements of the acceptance criteria. The cross-sectional capacity of the 4th to 7th floor bracing is less than the requirement, 243.8926 kN < 371.76 kN. The cross-sectional capacity of beam B1 is less than the requirement, 19.747 kNm < 22.2681 kNm. Story drift deficiency occurs on 1st to 3rd floor. Therefore, it has deficiency on Global Strength and Global Stiffness.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectEvaluationen_US
dc.subjectSeismicen_US
dc.subjectExistingen_US
dc.subjectASCE 41-17en_US
dc.subjectODCBen_US
dc.titleEvaluasi Seismik Bangunan Eksisting Berdasarkan ASCE 41-17 (Studi Kasus Menara Stadion Teladan)en_US
dc.title.alternativeSeismic Evaluation of Existing Building Based on ASCE 41-17 (Case Study of Teladan Stadium Tower)en_US
dc.typeThesisen_US
dc.identifier.nimNIM210404054
dc.identifier.nidnNIDN0006128204
dc.identifier.kodeprodiKODEPRODI22201#Teknik Sipil
dc.description.pages228 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US
dc.subject.sdgsSDGs 11. Sustainable Cities And Communitiesen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record