• Login
    View Item 
    •   USU-IR Home
    • Faculty of Agriculture
    • Department of Agricultural Engineering and Biosystem
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Agriculture
    • Department of Agricultural Engineering and Biosystem
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Uji Ruang Penyimpan Sistem Refrigerasi Absorpsi pada Beberapa Bahan Pertanian

    Test of Absorption Refrigeration System Storage Room for Several Agricultural Materials

    Thumbnail
    View/Open
    Cover (536.7Kb)
    Fulltext (1.560Mb)
    Date
    2024
    Author
    Taufik, Ahmad
    Advisor(s)
    Panggabean, Sulastri
    Metadata
    Show full item record
    Abstract
    Agricultural materials are susceptible to damage. To reduce the risk of damage, action needs to be taken, one of which is the storage process. Transportation is ongoing storage, because shrinkage often occurs during transportation, it is necessary to control the temperature during the transportation process. Cooling is a process of controlling temperature by lowering the temperature, one of which is used is the absorption cycle. The absorption refrigeration system is considered more economical because the compressor is replaced with a generator and absorber. This research aims to determine the effect of several varieties of agricultural products, weight of agricultural products and time on the performance of agricultural product storage space with an absorption refrigeration system. In this research, a method was carried out using a factorial completely randomized design (CRD) consisting of three factors. The results of the research show that the largest decrease in cooling room temperature was at a weight of 2 Kg with an average temperature of 9.31 oC. The largest decrease in cooling room temperature was at 180 minutes with an average temperature of 10.24oC. The lowest cooling load is at 2 Kg with an average of 6.15 watts. The lowest cooling load was at 60 minutes with an average of 6.59 watts. The highest COP value was at a weight of 2 Kg with an average of 10.80. The highest COP value was at 60 minutes with an average of 12.00. So it can be concluded that the variety of agricultural products, weight of agricultural products and time have a significant effect on the performance of agricultural product storage space with an absorption refrigeration system.
    URI
    https://repositori.usu.ac.id/handle/123456789/103897
    Collections
    • Undergraduate Theses [1017]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV