dc.description.abstractIn seismically active regions like Indonesia, steel is the preferred material for wide- span industrial buildings due to its quality, ductility, and efficiency in resisting earthquake forces. The gable roof frame structure, commonly used for spans of 20- 40 meters, employs non-prismatic sections to reduce material use and costs. This study examines the optimization of column spacing in such structures, a key factor affecting cost, space efficiency, and structural strength. Three models with column spacings of 6m, 8m, and 10m were analyzed using ETABS software, evaluating performance under gravity, wind, and earthquake loads. The study assessed material usage and deflection behavior, finding that all models were deemed safe based on structural analysis. Model 2 with an 8-meter column spacing used the least material, amounting to 1248.7 kN (127.34 tons), 32.28% less than Model 1 (1651.9 kN or 168.45 tons) and 2.33% less than Model 3 (1277.9 kN or 130.32 tons). However, Model 3 with a 10-meter column spacing exhibited the smallest vertical and horizontal deflections, indicating superior structural performance.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectsteel structureen_US
dc.subjectgable roof frameen_US
dc.subjectcolumn spacingen_US
dc.subjectstructural optimizationen_US
dc.subjectmaterial efficiencyen_US
dc.subjectmaterial efficiencyen_US
dc.subjectdeflectionen_US
dc.subjectseismic regionen_US
dc.subjectETABSen_US
dc.subjectindustrial buildingen_US
dc.subjectearthquake-resistanten_US
dc.titleStudi Analisis Perbandingan Struktur Gable Frame Menggunakan Profil Baja I Non-Prismatis (Tapered) dengan Konfigurasi Variasi Jarak Kolom terhadap Berat Material Bangunanen_US
dc.title.alternativeStudy Analysis Comparison of Gable Frame Structure Using Non-Prismatic (Tapered) I-Steel Profile with Configuration of Column Distance Variation on Building Material Weighten_US
dc.typeThesisen_US
dc.identifier.nimNIM200404065
dc.identifier.nidnNIDN0024125605
dc.identifier.kodeprodiKODEPRODI22201#Teknik Sipil
dc.description.pages101 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US
dc.subject.sdgsSDGs 9. Industry Innovation And Infrastructureen_US