• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Mechanical Engineering
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Mechanical Engineering
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Simulasi Distribusi Temperatur Pada Kotak Pendingin Ikan Berkapasitas 60 kg Dengan Software Ansys Fluent

    Simulation Of Temperature Distribution In A 60 kg Capacity Fish Cooling Box Using Ansys Fluent Software

    Thumbnail
    View/Open
    Cover (1.066Mb)
    Fulltext (4.180Mb)
    Date
    2025
    Author
    Sembiring, Edi Suranta
    Advisor(s)
    Nasution, Dian Morfi
    Metadata
    Show full item record
    Abstract
    A cooling kotak is a domestic refrigeration system used to store food items such as fish by inhibiting bacterial growth, thereby extending shelf life. Currently, R-134a is a commonly used refrigerant in cooling box, but it poses a significant risk to global warming (GWP = 1430). This study aims to analyze the performance of a 60-kg capacity fish cooling box using R-134a and R-600a refrigerants through Computational Fluid Dynamics (CFD) simulation using ANSYS Fluent. The evaluated parameters include heat absorbed by the evaporator, temperature distribution, and the Coefficient of Performance (COP). The study employed several variables: independent variables included R-134a with a mass flow rate of 0.0136 kg/s, outlet pressure of 512.12 kPa, and evaporator temperatur of -8.6°C; and R-600a with a mass flow rate of 0.0086 kg/s, outlet pressure of 252.25 kPa, and evaporator temperatur of -10.9°C. Dependent variables included the COP of the fish cooling box, evaporator capacity for cooling 60 kg of fish, the effect of temperature distribution on system performance, and a comparative analysis of the effectiveness of R-134a and R-600a. Simulation results show that R-134a yields a higher heat transfer rate of 28,356.62 W and more uniform temperatur distribution (±3.16°C between fish) compared to R-600a (25,819.84 W and ±6°C). This performance is supported by R-134a’s higher density (1.344 kg/m³), which ensures stable refrigerant flow. However, R-600a is environmentally superior with a significantly lower Global Warming Potential (GWP ≈ 3) compared to R-134a and requires less compressor work (0.44 kW versus 0.48 kW for R-134a). Although R-134a achieves a slightly higher COP of 2.45 compared to R-600a’s 2.4, R-600a remains a competitive and eco-friendly alternative.
    URI
    https://repositori.usu.ac.id/handle/123456789/105132
    Collections
    • Undergraduate Theses [922]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV