    Analisis Efek P-Delta pada Desain Struktur Baja dengan Sistem Rangka Bresing Eksentrik (SRBE) Menggunakan Software Midas Gen

    Analysis of P-Delta Effect in Steel Structure Design with Eccentrically Braced Frame System (EBF) Using Midas Gen Software

    Thumbnail
    View/Open
    Cover (3.017Mb)
    Fulltext (21.52Mb)
    Date
    2025
    Author
    Tanjung, Sissy Frisia
    Advisor(s)
    Tarigan, Johannes
    Metadata
    Show full item record
    Abstract
    Multi-story buildings with steel structures require a reliable lateral force damping system to anticipate seismic loads. One effective system in this regard is the Eccentrically Braced Frame (EBF), which combines stiffness and deformation capacity (ductility) through connecting elements called links. One important aspect affecting the behavior of this structure is the P-Delta effect, which is a form of geometric nonlinearity caused by the interaction between axial forces and lateral displacement, particularly significant in high-rise structures.This study aims to evaluate and compare the impact of the P-Delta effect on the performance of multi-story steel structures using two types of EBF configurations: Split K and V. The study was conducted through numerical simulation using MIDAS Gen 2023 software on a 10-story building model. The parameters analyzed include total displacement, interstory drift, stability coefficient, and moments.Based on the analysis results, it was found that the eccentric bracing configuration of type V demonstrated superior structural performance compared to type Split K, as evidenced by smaller values of displacement and interstory drift. The P-Delta effect caused an average increase in displacement,interstory drift, and stability coefficient ranging from 0% to 3% compared to the model that did not consider this effect. However, all results remain within the tolerance limits set by SNI 1726:2019. Therefore, the application of the V-type EBF system and consideration of the P-Delta effect in the design process are recommended for multi-story steel structures located in earthquake-prone areas.
    URI
    https://repositori.usu.ac.id/handle/123456789/105701
    Collections
    • Undergraduate Theses [1543]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV