dc.contributor.advisor | Nainggolan, Dr. Irwana | |
dc.contributor.author | Nabiilah | |
dc.date.accessioned | 2025-07-25T01:48:37Z | |
dc.date.available | 2025-07-25T01:48:37Z | |
dc.date.issued | 2025 | |
dc.identifier.uri | https://repositori.usu.ac.id/handle/123456789/107332 | |
dc.description.abstract | Nitrite is a dangerous substance contained in drinking water. The objective
of this analysis is to determine the Nitrite (NO2-) content analyzed at the UPT.
North Sumatra Provincial Health Laboratory. Data were taken from various
different drinking sources. Analysis of Nitrite (NO2-) content using the
Spectrophotometry (UV Vis) method. The results showed significant variations
in the concentration of these parameters, reflecting the complexity of the drinking
water consumed. Samples were taken from several locations in certain villages in
North Sumatra and then codes were used as each label of the sample.
Determination of nitrite levels was carried out according to the
spectrophotometric method in accordance with the procedures and uv visible
spectrophotometer tools used at the UPT. North Sumatra Provincial Health
Laboratory. The analysis results were obtained on the AM (Drinking Water)
sample solution with code 0004 AM (Drinking Water) label with a concentration
value of 0006 mg/L, code 0006 AM (Drinking Water) label with a concentration
value of 0008 mg/L, 0007 AM (Drinking Water) label with a concentration value
of 0012 mg/L, and 0018 AM (Drinking Water) label with a concentration value of
0010 mg/L. While for the sample solution with code 0019 AM (Drinking Water)
label, the concentration cannot be detected or Not In Valid Range. Based on the
data from the analysis results, it can be concluded that the nitrite (NO2-) content
in the sample code solutions 0004, 0006, 0007 and 0018 contains a lower
concentration of nitrite than the regulations that have been established and meets
the maximum limit requirements for nitrite content in drinking water. However,
the concentration of the sample solution with code 0019 labeled AM (Drinking
Water) could not be detected. The reason refers to the very high probability that
the sample solution does not contain nitrite. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Sumatera Utara | en_US |
dc.subject | Drinking Water | en_US |
dc.subject | Nitrite | en_US |
dc.subject | Spectrophotometry (UV Vis) | en_US |
dc.title | Analisis Kandungan Nitrit (NO2- ) Pada Air Minum di UPT. Laboratorium Kesehatan Daerah Provinsi Sumatera Utara dengan Menggunakan Metode Spektrofotometri UV Visible | en_US |
dc.title.alternative | Analysis of Nitrite (NO2-) Content in Drinking Water at UPT. North Sumatra Province Regional Health Laboratory Using the UV Vis Spectrophotometer Method | en_US |
dc.type | Thesis | en_US |
dc.identifier.nim | NIM222401029 | |
dc.identifier.nidn | NIDN0013017908 | |
dc.description.pages | 51 Pages | en_US |
dc.description.type | Kertas Karya Diploma | en_US |
dc.subject.sdgs | SDGs 9. Industry Innovation And Infrastructure | en_US |