Show simple item record

dc.contributor.advisorHandana, Muhammad Agung Putra
dc.contributor.authorSiregar, Ahmad Naufal Al-Arif
dc.date.accessioned2025-07-28T07:40:34Z
dc.date.available2025-07-28T07:40:34Z
dc.date.issued2025
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/107677
dc.description.abstractIndonesia is located within the Pacific Ring of Fire, making it highly vulnerable to seismic hazards. One of the key efforts to reduce the risk of earthquake-induced damage is by evaluating existing building structures using established standards. One widely adopted standard is ASCE 41-17 (American Society of Civil Engineers), which plays a significant role in assessing the seismic performance of building structures. This standard applies a performance-based design approach, with evaluation levels ranging from Tier 1 to Tier 3, and performance objectives including Immediate Occupancy (IO), Life Safety (LS), and Collapse Prevention (CP) This study focuses on the structural assessment of Building C at Mitra Sejati Hospital in Medan, constructed in 2001 with five floors. The structure was originally designed based on SNI 03-1726-1989, which was applicable at the time. However, with the adoption of the updated SNI 1726:2019 and the need for more accurate seismic evaluation, the building requires reassessment using the latest methods The assessment was conducted using the ASCE 41-17 guidelines through a multi-tiered approach: Tier 1 (Screening) and Tier 2 (Deficiency-Based Evaluation). Tier 1 involved a Quick Check Analysis, examining the structural configuration and performance using a Systematic Structural Checklist. The results indicated that several structural elements fell under Noncompliant or Unknown categories, necessitating further evaluation under Tier 2. In this stage, the Linear Dynamic Procedure (LDP) was used to assess structural responses such as displacement, shear forces, and moment under seismic loads. The Tier 2 analysis showed that the structural components were only capable of achieving Life Safety (LS) and Immediate Occupancy (IO) performance levels in certain areas, indicating that the building does not fully comply with current safety requirements for strong earthquake events. Therefore, strengthening strategies and full implementation of ASCE 41-17 are essential to ensure the structural safety of the building in the event of future seismic activity.en_US
dc.language.isoiden_US
dc.publisherAhmad Naufal Al-Arif Siregaren_US
dc.subjectSeismic Evaluationen_US
dc.subjectASCE 41-17en_US
dc.subjectMitra Sejati Hospitalen_US
dc.subjectTier 1en_US
dc.subjectTier 2en_US
dc.subjectLinear Dynamic Procedureen_US
dc.subjectExisting Buildingen_US
dc.titleEvaluasi Seismik Bangunan Beton Bertulangan Eksisting Berdasarkan ASCE 41-17 (Studi Kasus Gedung RS Mitra Sejati Medan)en_US
dc.title.alternativeSeismic Evaluation of Existing Reinforced Concrete Building Based on ASCE 41-17 (Case Study: Mitra Sejati Hospital Building, Medan)en_US
dc.typeThesisen_US
dc.identifier.nimNIM210404069
dc.identifier.nidnNIDN 0006128204
dc.identifier.kodeprodiKODEPRODI22201#Teknik Sipil
dc.description.pages88 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US
dc.subject.sdgsSDGs 9. Industry Innovation And Infrastructureen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record