Show simple item record

dc.contributor.advisorHandana, Muhammad Agung Putra
dc.contributor.authorHutagalung, Albert Timothy
dc.date.accessioned2025-07-29T07:15:21Z
dc.date.available2025-07-29T07:15:21Z
dc.date.issued2025
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/107808
dc.description.abstractThis research investigates the mechanical performance of concrete incorporating fly ash as a partial cement replacement subjected to high temperature exposure. Fly ash sourced from the Pangkalan Susu power plant was utilized in replacement proportions of 0%, 10%, 20%, 30%, 40%, and 50%. Concrete specimens aged 28 days were evaluated using non destructive testing methods, namely Ultrasonic Pulse Velocity (UPV) and Rebound Hammer, as well as a destructive testing method, the Compression Test. All specimens were exposed to a temperature of 1000OC for 3 hours followed by cooling through water immersion. Post fire UPV testing demonstrated an optimum compressive strength of 13 MPa in the 0% fly ash mix. Conversely, the Rebound Hammer Test yielded a maximum compressive strength of 2,05 MPa for the 10% fly ash variation. It is noteworthy that Rebound Hammer measurements were only perfomed on specimens containing 0% and 10% fly ash, as those incorporating higher replacement levels (20%-50%) exhibited extensive cracking that rendered them unsuitable for testing. The Compression Test conducted on post heated specimens recorded an optimum compressive strength estimations most closely aligned with those obtained from destructive testing, underscoring its potential utility for assessing residual strength in fire exposed concrete.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectFly Ashen_US
dc.subjectHigh Temperatureen_US
dc.subjectResidual Strengthen_US
dc.subjectNon Destructive Testingen_US
dc.subjectCompression Testen_US
dc.titlePerbandingan Karakteristik Pengujian Non Destructive Test (NDT) dalam Beton Fly Ash sebagai Bahan Substitusi Parsial Semen terhadap Suhu 1000OCen_US
dc.title.alternativeCharacteristics Comparison of Non-Destructive Testing (NDT Method) in Fly Ash Concrete as a Partial Cement Substitution Material at a Temperature of 1000°Cen_US
dc.typeThesisen_US
dc.identifier.nimNIM200404151
dc.identifier.nidnNIDN0006128204
dc.identifier.kodeprodiKODEPRODI22201#Teknik Sipil
dc.description.pages127 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US
dc.subject.sdgsSDGs 4. Quality Educationen_US