    Simulasi Penambahan Sistem Kabut Air pada Model Air-Cooled Heat Exchanger (ACHE) dengan Menggunakan Software Ansys

    Simulation of Water Mist System Addition on Air Cooled Heat Exchanger (Ache) Model Using Ansys Software

    Thumbnail
    View/Open
    Cover (4.409Mb)
    Fulltext (7.138Mb)
    Date
    2025
    Author
    Wijaya, Mhd Yhoga Ananta
    Advisor(s)
    Ambarita, Himsar
    Metadata
    Show full item record
    Abstract
    The function of an Air-Cooled Heat Exchanger (ACHE) is to serve as a cooling system that utilizes ambient air as the cooling medium. One of the advantages of using air is its low cost and abundant availability in the surrounding environment. However, a major drawback of ACHE is its low thermal performance due to the relatively low heat transfer coefficient on the air side, which is also influenced by the ambient air temperature (Ta). In this study, the author conducted a simulation of an ACHE system enhanced with a water mist spray using Ansys software. This study employs Computational Fluid Dynamics (CFD) to determine the optimal water spray rate for the misting system based on the ambient air temperature (Ta). The amount of water sprayed varies from 0 kg/h, 2 kg/h, 4 kg/h, 6 kg/h, and 8 kg/h. At an ambient temperature of 303.15 K, the cooling effect on the pipe outlet temperature increased by 35.39 K, 38.24 K, 39.35 K, 40.38 K, and 46.29 K, respectively. At an ambient temperature of 313.15 K, the cooling effect increased by 31.02 K, 33.40 K, 34.73 K, 35.71 K, and 40.71 K, respectively. Under the thermal conditions of the Sarulla Geothermal Power Plant (PLTP Sarulla), the cooling effect on the pipe outlet temperature increased by 36.12 K, 39.1 K, 40.06 K, 40.62 K, and 45.35 K, respectively.
    URI
    https://repositori.usu.ac.id/handle/123456789/107837
    Collections
    • Undergraduate Theses [963]

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV