dc.description.abstractThis study aims to optimize the CO₂ laser cutting process in the manufacture of implant tissue plates used for fracture fixation in the human skull. The design of the implant tissue plate was modified to be more compatible with the anatomical geometry and minimize the risk of additional injury. The optimization method used is Taguchi-Grey Relational Analysis (GRA), which allows the identification of the best combination of cutting parameters to produce optimal product quality. The results showed that the optimal combination of cutting parameters was 360 W power, 40 mm/min cutting speed, 0.5 mm nozzle distance, 6 Pa gas pressure, and 1 mm material thickness. Analysis of variance (ANOVA) indicated that material thickness had the greatest contribution to cutting quality, especially in reducing dimensional deviations and the number of burrs formed. Confirmation experiments showed an increase in Grey Relational Grade (GRG) of 11.26%, which proved the effectiveness of the optimization method applied. These findings have important implications for the development of laser cutting-based manufacturing techniques for medical applications, especially in the production of high-precision implants. Further studies are recommended to evaluate the mechanical characteristics of the implant after insertion and to examine the effect of variations in other parameters on the long-term performance of the implant.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectImplant mesh plateen_US
dc.subjectCO₂ laseren_US
dc.subjectTaguchi-GRAen_US
dc.subjectCutting optimizationen_US
dc.subjectGrey Relational Analysis (GRA)en_US
dc.titleAplikasi Pemotongan Laser Co2 untuk Produksi Pelat Jejaring Implan Medis Berbahan Stainless Steel 316len_US
dc.title.alternativeCo2 Laser Cutting Application for Production of Medical Implant Tissue Plates Made from 316l Stainless Steelen_US
dc.typeThesisen_US
dc.identifier.nimNIM217015005
dc.identifier.nidnNIDN0007086804
dc.identifier.kodeprodiKODEPRODI21101#Teknik Mesin
dc.description.pages162 Pagesen_US
dc.description.typeTesis Magisteren_US
dc.subject.sdgsSDGs 9. Industry Innovation And Infrastructureen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record