dc.description.abstractSpun Pile foundations are the primary solution for the construction of multi story buildings in areas with unfavorable soil conditions, such as in the city of Medan. This study analyzes the axial bearing capacity and settlement of 60 cm diameter Spun Pile foundations in the Tower-1 Inpatient Building Project at Haji Medan Hospital by comparing three approaches: an empirical method based on SPT data, static load testing, and numerical simulation using PLAXIS 3D with Mohr-Coulomb and Hardening Soil soil models. The analysis results show that the empirical method yields an ultimate bearing capacity of 321,9 tons, while the interpretation of field load tests (Davisson, Mazurkiewicz, and Chin) provides values of 410 tons, 430 tons, and 476 tons, respectively. The PLAXIS 3D simulation showed conservative results with a deviation of less than 6% compared to field data, where the Hardening Soil model (8.053 mm settlement) was more accurate than the Mohr-Coulomb model (10.19 mm) in predicting the actual settlement of 6.66 mm. Additionally, pile group efficiency analysis yielded values of 75 83.34%, indicating the influence of pile-to-pile interaction on bearing capacity. This study concludes that PLAXIS 3D modeling with the Hardening Soil model can provide more realistic predictions for Spun Pile foundation design and serve as a reference for similar projects in regions with similar soil characteristics.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectSpun Pileen_US
dc.subjectaxial load capacityen_US
dc.subjectPLAXIS 3Den_US
dc.subjectstatic load testen_US
dc.subjectSPTen_US
dc.subjectfinite element methoden_US
dc.titleAnalisis Daya Dukung Aksial Spun Pile Diameter 60 Cm Menggunakan Uji Beban Statik dan Pemodelan Elemen Hingga (Plaxis 3d) Berdasarkan Data Bh-2 Pada Proyek Gedung Rawat Inap Tower-1 Rs Haji Medanen_US
dc.title.alternativeAnalysis Of The Axial Bearing Capacity Of A 60 Cm Diameter Spun Pile Using Static Load Testing And Finite Element Modeling (Plaxis 3d) Based On Bh-2 Data For The Tower-1 Inpatient Building Project At Haji Hospital Medanen_US
dc.typeThesisen_US
dc.identifier.nimNIM227016028
dc.identifier.nidnNIDN0006047202
dc.identifier.kodeprodiKODEPRODI22101#Teknik Sipil
dc.description.pages161 Pagesen_US
dc.description.typeTesis Magisteren_US
dc.subject.sdgsSDGs 9. Industry Innovation And Infrastructureen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record