    Analisis Kualitas Udara dalam Ruang dan Hubungannya dengan Sick Building Syndrome di Ruang Rawat Inap Rumah Sakit Prof. Dr. Chairuddin P. Lubis USU

    Indoor Air Quality and Its Association with Sick Building Syndrome in Inpatient Wards of Prof. Dr. Chairuddin P. Lubis USU Hospital

    Thumbnail
    View/Open
    Cover (568.1Kb)
    Fulltext (2.759Mb)
    Date
    2025
    Author
    Salsabil, Sakha
    Advisor(s)
    Khair, Hafizhul
    Metadata
    Show full item record
    Abstract
    Indoor Air Quality (IAQ) in hospital inpatient rooms plays an important role in occupant health and has the potential to trigger complaints of Sick Building Syndrome (SBS). This study aimed to analyze indoor air quality, identify symptoms of SBS, and examine the association between indoor air quality parameters and the occurrence of SBS in inpatient rooms at Prof. dr. Chairuddin P. Lubis University Hospital. A cross-sectional study design was applied, with independent variables consisting of temperature, humidity, lighting, ventilation rate, PM2.5, PM10, CO2, TVOC, and airborne microbial count, while the dependent variable being SBS. Measurements of indoor air quality were conducted directly using measuring instruments in eight inpatient rooms over three consecutive days, while SBS symptom data were collected through questionnaires completed by patient companions present in the rooms. The results showed that lighting (91.1–410.7 lux), PM2.5 (4.9–6.3 μg/m³), PM10 (6.7–10 μg/m³), CO2 (407–421.8 ppm), and TVOC (0.028–0.077 ppm) met the quality standards, whereas temperature (24.1–29.4°C), humidity (53.9–63.6%RH), ventilation rate (0–0.2 m/s) exceeded the threshold limits set by the Indonesian Ministry of Health Regulation No. 2 of 2023, and airborne bacteria (602.5–2298.8 CFU/m³) exceeded the limit specified in the Decree of the Minister of Health No. 1204 of 2004. The highest prevalence of SBS was found in the Cendana 4 inpatient room (100%), with the most frequently reported symptoms being drowsiness and stress, sneezing, flu, coughing, fatigue, and lethargy. Chi-square statistical analysis revealed no significant association between indoor air quality parameters and the occurrence of SBS (p-value > 0.05). The occurrence of SBS in inpatient rooms is not influenced by a single parameter but is multifactorial in nature.
    URI
    https://repositori.usu.ac.id/handle/123456789/111145
    Collections
    • Undergraduate Theses [428]

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV