Show simple item record

dc.contributor.advisorHumaidi, Syahrul
dc.contributor.advisorRamdan, Dadan
dc.contributor.advisorTarigan, Kerista
dc.contributor.authorFrianto, Herri Trisna
dc.date.accessioned2026-01-06T04:32:23Z
dc.date.available2026-01-06T04:32:23Z
dc.date.issued2025
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/111793
dc.description.abstractThis study aims to analyze the frequency response of a fluid system controlled by a PID (Proportional-Integral-Derivative) controller using flow and pressure sensor data. Data were collected from a Multi-Loop Controller system to evaluate the performance and stability of the system in both household and industrial plumbing applications. Using Bode and Nyquist diagrams, the frequency response of the system was analyzed to assess the effectiveness of the designed PID controller. The research results show that at a frequency of 0.5 Hz, the system experiences a magnitude of -8 dB with a phase of -85°, while at a frequency of 50,000 Hz, the system shows a magnitude of 22 dB and a phase of 120°. Based on this analysis, the PID controller successfully maintained system stability with a frequency response that was consistent and aligned with theoretical predictions. No significant deviations were found in the sensor data used, confirming the accuracy and reliability of the controller in maintaining system performance. This study provides valuable insights into the application of PID controllers in fluid systems and reinforces the understanding of the impact of frequency response in ensuring overall system stability and performance..en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectPID controlleren_US
dc.subjectFrequency responseen_US
dc.subjectBode diagramen_US
dc.subjectNyquist diagramen_US
dc.subjectFluid systemen_US
dc.titleAnalisis Respons Frekuensi Bode dan Nyquist pada Pengendali PID Berdasarkan Data Sensor Aliran dan Tekanan dalam Multi Loop Controller pada Sistem Fluidaen_US
dc.title.alternativeAnalysis Of Bode And Nyquist Frequency Response In Pid Controllers Based On Flow And Pressure Sensor Data In A Multi-Loop Controller For Fluid Systemsen_US
dc.typeThesisen_US
dc.identifier.nimNIM188108008
dc.identifier.nidnNIDN0017066501
dc.identifier.nidnNIDN0003026001
dc.identifier.kodeprodiKODEPRODI45001#Ilmu Fisika
dc.description.pages129 Pagesen_US
dc.description.typeDisertasi Doktoren_US
dc.subject.sdgsSDGs 7. Affordable And Clean Energyen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record