Show simple item record

dc.contributor.advisorSyam, Bustami
dc.contributor.advisorWirjosentono, Basuki
dc.contributor.authorKarya, Raja E
dc.date.accessioned2019-06-14T01:55:28Z
dc.date.available2019-06-14T01:55:28Z
dc.date.issued2019
dc.identifier.urihttp://repositori.usu.ac.id/handle/123456789/15181
dc.description.abstractPada zaman modern ini, kuda masih banyak dipergunakan dalam industry parawisata, untuk pengangkutan di daerah-daerah terpencil, untuk balapan dll. Salah satu factor penunjang yang sangat penting dalam pengoperasian kuda ini adalah sepatu kuda (horseshoe). Sepatu kuda yang terbuat dari material campuran polymeric foam yang diperkuar dengan fiberglass diuji dalam penelitian ini dan dibandingkan dengan material standard sepatu kuda yang paling banyak dipakai di seluruh dunia, yaitu sepatu kuda yang terbuat dari material Low Carbon Mild Steel A 36. Sepatu kuda dengan ukuran 111,60 mm x 106,30 disimulasi secara statik lalu dibandingkan hasilnya dengan hasil simulasi statik material standard sepatu kuda, yaitu Low Carbon Mild Steel A 36. Untuk posisi kuda berdiri dalam keadaan diam, diperoleh Equivalent Stress untuk material polymeric foam A, B dan C secara berturut-turut adalah 0,60467 MPa, 0,4874 MPa dan 0,61678 MPa. Sedang untuk LCMS A 36 adalah 0,56 MPa. Jadi tegangan pada polymeric foam, 60647 dan polymeric foam C 0,61678 MPa adalah lebih besar dari tegangan yang terjadi pada LCMS A36, yaitu 0,56 MPa. Untuk Normal Stress pada polymeric foam A, tegangan yang terjadi pada sumbu-X dan sumbu Z adalah 0,044 MPa dan 0,044 MPa. Untuk polymeric foam C, Normal Stress yang terjadi pada sumbu X kuda a berlari dengan kecepatan konstan,adalah 0,071 MPa dan sumbu Z adalah 0,083 MPa. Sedang tegangan yang terjadi pada LCMS A 36 pada sumbu X adalah 0.042 MPa sedang pada sumbu Z adalah 0,042 MPa. Untuk posisi kuda berlari dengan kecepatan konstan, didapat Equivalent Stress untuk Polymeric foam A adalah 8,3434 MPa dan untuk polymeric foam C adalah 8,40 MPa. Sedang untuk LCMS A 36 adalah 7,775 MPa. Untuk Normal Stress, Polymeric foam A, pada sumbu X adalah 1,77 MPa, untuk sumbu Z adalah 0,61 MPa. Polymeric foam C, sumbu X adalah 1,21 MPa dan sumbu Z adalah 0,505 MPa. Sedang LCMS A 36, sumbu X adalah 1,09 dan sumbu Z adalah 0,41. Untuk Air Gun Compressor, diperoleh tegangan spesimen untuk jarak impak mulai 100 mm sampai 1000 mm adalah 1,8729 MPa sampai 24,5772 MPa. Sedang untuk simulasi dinamik dengan jarak 100 mm sampai 1000 mm diperoleh hasil tegangan adalah 2,0756 MPa sampai 24,835 MPa. Dari hasil tegangan dapat dilihat bahwa tegangan yang dihasilkan dari percobaan experimental Air Gun Compressor ternyata hampir sama besar dengan tegangan dari hasil simulasi . Pada tegangan maksimum 24,5772 MPa yang diperoleh dalam percobaan impak kecepatan tinggi AGC, spesimen sepatu kuda patah setelah diimpak selama 4 (empat) kali. Dari hasil percobaan dapat disimpulkan bahwa percobaan ini berhasil dan material sepatu kuda yang terdiri dari polymeric foam diperkuat fiberglass, dapat direkomendasikan menjadi material alternatif sepatu kuda pengganti material standard LCMS A 36.en_US
dc.description.abstractIn this modern era, horses are still widely used in tourism industries, for transportation in remote areas, for racing etc. One of the most important supporting factors in the operation of this horse is horseshoe. Horseshoes made from a mixture of polymeric foam materials that are added with fiberglass are tested in this study and compared to the standard horse shoe material that is most widely used in the whole world, named horseshoes made of Low Carbon Mild Steel A 36. Horse shoes with size 111.60 mm x 106.30 were simulated statically and then the results compared with the static simulation of standard horse shoes, named Low Carbon Mild Steel A 36. For standing horse position in a stationary state, Equivalent Stress was obtained for polymeric foam A, B and C in a row are 0.60467 MPa, 0.4874 MPa and 0.61678 MPa. As for LCMS A 36 is 0.56 MPa. So the voltage on polymeric foam), 60647 and polymeric foam C 0.61678 MPa is greater than the voltage that occurs in LCMS A36, which is 0.56 MPa. For Normal Stress on polymeric foam A, the stresses that occur on the X-axis and Z-axis are 0.044 MPa and 0.044 MPa. For polymeric foam C, the Normal Stress that occurs on the X axis of a horse runs at a constant speed, is 0.071 MPa and the Z axis is 0.083 MPa. While the stress that occurs on the LCMS A 36 on the X axis is 0.042 MPa, on the Z axis is 0.042 MPa. For horse position running at constant speed, Equivalent Stress for Polymeric foam A is 8,3434 MPa and for polymeric foam C is 8,40 MPa. As for LCMS A 36 is 7.775 MPa. For Normal Stress, polymeric foam A, on the X axis is 1.77 MPa, for the Z axis is 0.61 MPa. Polymeric foam C, the X axis is 1.21 MPa and the Z axis is 0.505 MPa. Medium LCMS A 36, X axis is 1.09 and Z axis is 0.41. For Air Gun Compressor, the specimen voltage obtained for impact distances ranging from 100 mm to 1000 mm is 1.8729 MPa to 24.5772 MPa. As for the dynamic simulation with a distance of 100 mm to 1000 mm the results of the voltage are 2.0756 MPa to 24.835 MPa. From the results it can be seen that the stresses generated from experimental Air Gun Compressor turns out to be almost as large as the voltage from the simulation results. At a maximum voltage of 24,5772 MPa obtained in an AGC high speed impact experiment, the horse shoe specimen is broken after being impregnated for 4 (four) times. From the results of the experiment it can be concluded that this experiment was successful and the horseshoe material consisting of polymeric foam reinforced fiberglass, can be recommended to be an alternative material for horse shoe replacement for LCMS A 36 standard material.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectMaterial Alternativeen_US
dc.subjectSepatu Kudaen_US
dc.subjectPolymeric Foamen_US
dc.subjectImpak Kecepatan Tinggien_US
dc.subjectTegangan dan Simulasien_US
dc.titleAnalisa Respon Mekanik Material Alternatif untuk Sepatu Kuda Berbahan Dasar Polymeric Foam Diperkuat Fiberglass dengan Menggunakan Software Ansysen_US
dc.typeThesisen_US
dc.identifier.nimNIM167015013
dc.description.pages199 Halamanen_US
dc.description.typeTesis Magisteren_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record