    Optimasi Kualitas Citra dan Dosis Radiasi dengan Menggunakan Computed Radiografi pada Pemeriksaan Cranium

    View/Open
    Fulltext (1.537Mb)
    Date
    2019
    Author
    Nasution, Prida Vitary
    Advisor(s)
    Ginting, Herli
    Metadata
    Show full item record
    Abstract
    Telah dilakukan penelitian pengaruh penggunaan tegangan tabung 125 kV, 80 kV, 65 kV pada pemeriksaan cranium anteroposterior.Penelitian ini bertujuan untuk mengetahui kualitas citra gambaran dan nilai dosis radiasi serap pada foto cranium yang diterima oleh pasien.Metode yang digunakan dalam penelitian ini yaitu kualitas citra dan dosis serap dianalisis dengan menggunakan data dari tegangan tabung (kV) dan beban tabung (mAs) pada jarak 100 cm dari objek.Dari penelitian diperoleh bahwa penggunaan teknik tegangan tabung (kV) tinggi menyebabkan nilai densitas menurun dibandingkan pada teknik tegangan tabung (kV) standar dan tegangan tabung (kV) rendah.Kontras tertinggi untuk variasi arus tegangan tabung 65 (kV) dan 16 mAs, dan kontras terendah untuk variasp tegangan tabung 125 (kV) dan 25 mAs., dan dosis serap radiasi yang diterima oleh pasien yang paling besar adalah pada tegangan tabung (kV) 125 dan 25 mAs.
     
    This research measures the influence of kV 125, 80, 60 of cranium anteroposterior and lateral. The study aims for identify image quality and examination towards dose of cranium. The method used in this research that absorbed dose is analyzed using data from the voltage (kV), tube load (mAs) at distance 100 cm from the object. From the research, it was found that the use of high kV technique caused a decrease in density compared to the standard kV and low kV technique. The highest contrast for current variations is 65 kV and 16 mAs, and the lowest contrast is for variations of 125 Kv and 25 mAsand the highest absorption dose of radiation received by patients is at kV 125 and 25 mAs.

    URI
    http://repositori.usu.ac.id/handle/123456789/23891
    Collections
    • Undergraduate Theses [1320]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV