    Analisis Paparan Radiasi Terhadap Keluarga Pasien pada Pemeriksaan CT-Scan Head dengan Jarak dan Ketebalan Apron yang Berbeda

    View/Open
    Fulltext (1.294Mb)
    Date
    2019
    Author
    Tarigan, Tomi Franedsa
    Advisor(s)
    Sembiring, Timbangen
    Metadata
    Show full item record
    Abstract
    CT Scan adalah singkatan dari Computerized Tomography Scan, suatu alat pencitraan atau prosedur medis untuk menggambarkan bagian-bagian tubuh tertentu menggunakan bantuan sinar-X khusus. Penelitian ini dilakukan di Rumah Sakit Umum Vina Estetica. Telah dilakukan pengukuran paparan radiasi terhadap keluarga pasien dengan menggunakan alat ukur radiasi perorangan yang dapat dibaca langsung (pendose) . Percobaan dilakukan sebanyak 10 (sepuluh) kali percobaan dengan menggunakan factor ekspose yang sama dan menggunakan alat pelindung radiasi perorangan (Apron) dengan ketebalan 0,35mm dengan jarak : 50cm, 75cm, 100cm, 125cm, 150cm dan alat pelindung radiasi perorangan (Apron) dengan ketebalan 0,50mm dengan jarak : 50cm, 75cm, 100cm, 125cm, 150cm. Pendose ditempelkan pada tubuh keluarga pasien yang telah terlindungi alat pelindung radiasi perorangan.
     
    CT Scan stands for Computerized Tomography Scan, an imaging device or medical procedure to describe certain body parts using the help of special X-rays. This research was conducted at Vina Estetica Hospital. Radiation exposure measurements have been carried out on the patient's family by using an individual radiation measuring device that can be read directly (pendose). The experiment was conducted 10 (ten) times using the same exposure factor and using individual radiation protective equipment (Apron) with a thickness of 0.35 mm with a distance: 50cm, 75cm, 100cm, 125cm, 150cm and individual radiation protective equipment (Apron) with thickness 0.50mm with distance: 50cm, 75cm, 100cm, 125cm, 150cm. Pendose was attached to the body of a patient's family who has been protected by an individual radiation protective device.

    URI
    http://repositori.usu.ac.id/handle/123456789/26235
    Collections
    • Undergraduate Theses [1320]

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara (RI-USU)
    Universitas Sumatera Utara | Perpustakaan | Resource Guide | Katalog Perpustakaan
    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV