Show simple item record

dc.contributor.advisorSembiring, Timbangen
dc.contributor.authorTarigan, Tomi Franedsa
dc.date.accessioned2020-06-19T02:41:56Z
dc.date.available2020-06-19T02:41:56Z
dc.date.issued2019
dc.identifier.urihttp://repositori.usu.ac.id/handle/123456789/26235
dc.description.abstractCT Scan adalah singkatan dari Computerized Tomography Scan, suatu alat pencitraan atau prosedur medis untuk menggambarkan bagian-bagian tubuh tertentu menggunakan bantuan sinar-X khusus. Penelitian ini dilakukan di Rumah Sakit Umum Vina Estetica. Telah dilakukan pengukuran paparan radiasi terhadap keluarga pasien dengan menggunakan alat ukur radiasi perorangan yang dapat dibaca langsung (pendose) . Percobaan dilakukan sebanyak 10 (sepuluh) kali percobaan dengan menggunakan factor ekspose yang sama dan menggunakan alat pelindung radiasi perorangan (Apron) dengan ketebalan 0,35mm dengan jarak : 50cm, 75cm, 100cm, 125cm, 150cm dan alat pelindung radiasi perorangan (Apron) dengan ketebalan 0,50mm dengan jarak : 50cm, 75cm, 100cm, 125cm, 150cm. Pendose ditempelkan pada tubuh keluarga pasien yang telah terlindungi alat pelindung radiasi perorangan.en_US
dc.description.abstractCT Scan stands for Computerized Tomography Scan, an imaging device or medical procedure to describe certain body parts using the help of special X-rays. This research was conducted at Vina Estetica Hospital. Radiation exposure measurements have been carried out on the patient's family by using an individual radiation measuring device that can be read directly (pendose). The experiment was conducted 10 (ten) times using the same exposure factor and using individual radiation protective equipment (Apron) with a thickness of 0.35 mm with a distance: 50cm, 75cm, 100cm, 125cm, 150cm and individual radiation protective equipment (Apron) with thickness 0.50mm with distance: 50cm, 75cm, 100cm, 125cm, 150cm. Pendose was attached to the body of a patient's family who has been protected by an individual radiation protective device.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectCT Scanen_US
dc.subjectPaparan Radiasien_US
dc.subjectAlat Ukur Radiasi Perorangan (Pendose)en_US
dc.subjectAlat Pelindung Radiasi Perorangan (Apron)en_US
dc.subjectJaraken_US
dc.titleAnalisis Paparan Radiasi Terhadap Keluarga Pasien pada Pemeriksaan CT-Scan Head dengan Jarak dan Ketebalan Apron yang Berbedaen_US
dc.typeThesisen_US
dc.identifier.nimNIM160821051
dc.description.pages45 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record