Show simple item record

dc.contributor.advisorBarus, Diana Alemin
dc.contributor.authorNababan, Supeto
dc.date.accessioned2020-09-25T03:12:08Z
dc.date.available2020-09-25T03:12:08Z
dc.date.issued2020
dc.identifier.urihttp://repositori.usu.ac.id/handle/123456789/27980
dc.description.abstractPenambahan lateks 60% yang cukup besar perbandingan dengan aspal penetrasi 60-70 akankah memenuhi standar mutu aspal pen 60-70. Dengan perbandingan laerks dan aspalnya adalah: 1000 gr aspal penetrasi 60-70 tampa penambahan karet (L0), 1000 gr aspal penetrasi 60-70 dengan 100 gr lateks kadar 60% atau 10 phr (L1), 1000 gr aspal penetrasi 60-70 dengan 200 gr lateks kadar 60% atau 20 phr (L2), 1000 gr aspal penetrasi 60-70 dengan 300 gr lateks kadar 60% atau 30 phr (L3), dan 1000 gr aspal penetrasi 60-70 dengan lateks kadar 60% atau 40 phr (L4). Semua sampel dihomogenkan dengan cara dipanaskan pada suhu 150oC dan 250 rpm dengan waktu 30 menit setiap sampelnya. Dimasukan kedalam cetakan setiap pengujian, didiamkan selama 30 menit lalu direndam kedalam bak perendaman selama 30 menit dengan suhu 25oC. Pengujian yang dilakukan ialah penetrasi, pengujian titik lembek, pengujian daktilitas, dan pengujian titik nyala dan bakar. Hasil uji fisis aspal untuk penambahaan phr lateks kadar 60% yang sesuai dengan standar aspal pen 60-70 ialah dengan 10 phr (L1) dan 20 phr (L2) yaitu nilai penetrasi aspal pada L1= 56 mm, L2= 65 mm,. Hasil uji titik lembek L1= 53 oC, L2= 53 oC. Hasil uji daktilitas L1= 104 cm, L2= 150 cm. Hasil uji titik nyala dan bakar L1= 221 oC dan 275 oC, L2= 255 oC dan 285 oC, untuk uji berat jenis tidak sesuai standar yaitu pada L1= 0,9317 gr/ml, L2= 0,9129 gr/ml.en_US
dc.description.abstractIncreasing latex 60% which ratio is enough with penetration of asphalt 60-70 will fully standard of penetration of asphalt 60-70 without increasing latex (L0), 1000 gr penetration of asphalt 60-70 with 100 gr latex with 60 % degree or 10 phr (L1), 1000 gr penetration of asphalt 60-70 with 200 gr latex 60% degree or 20 phr (L2), 1000 gr penetration of asphalt 60-70 with 300 gr latex 60 % degree or 30 phr (L3), 1000 gr penetration of asphalt 60-70 with 400 gr latex 60 % degree or 40 phr (L4). All of samples homogenized by headted at 150 oC temperature and 250 rpm with 30 minutes then soaked in the tub for 30 minutes with 25oC temperature penetration of asphalt 60-70 with 10 phr (L1) and 20 phr (L2) that asphalt penetration scoring in L1= 56 mm, L2= 65 mm. The result of flash and fire tester is L1= 221 oC and 275 oC, L2= 225 oC and 285OC for hard testing disagree with standard is L1= 0,9317 gr/ml, L2= 0,9129 gr/mlen_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectAspalen_US
dc.subjectlateksen_US
dc.subjectPenetrasien_US
dc.titlePengaruh Penambahan Lateks Kadar 60% terhadap Karakteristik Aspal Pen 60-70en_US
dc.typeThesisen_US
dc.identifier.nimNIM160801041
dc.description.pages70 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record