dc.contributor.advisor | Ginting, Junedi | |
dc.contributor.author | Rumapea, Maria Florentina | |
dc.date.accessioned | 2020-09-25T03:21:33Z | |
dc.date.available | 2020-09-25T03:21:33Z | |
dc.date.issued | 2020 | |
dc.identifier.uri | http://repositori.usu.ac.id/handle/123456789/27984 | |
dc.description.abstract | Telah dibuat sebuah sistem monitoring kesehatan dengan pemeriksaan tanda-tanda vital (TTV). Dalam penelitian ini berupa pengukuran terhadap detak jantung dan suhu tubuh dengan pemanfaatan sensor EKG AD8232 sebagai instrumentasi pengukuran nilai detak jantung berdasarkan elektrokardiogram dan ds18b20 untuk mengukur suhu tubuh. Monitoring dilakukan secara real time dengan sistem Internet of Things (IoT) melalui server thingspeak. Cara kerja alat cukup sederhana yaitu dengan mengirimkan sinyal analog ke mikrokontroler yaitu data suhu dan detak jantung berupa grafik EKG fluktuatif pada serial plotter yang akan diolah menjadi data BPM kemudian dikirimkan ke server thingspeak. Alat dapat berfungsi dengan baik berdasarkan pengujian sensor dimana persen ralat masing-masing sensor yang didapatkan yaitu 1,83% untuk pengukuran BPM oleh sensor EKG dan 0,63675% untuk pengukuran suhu tubuh oleh ds18b20. | en_US |
dc.description.abstract | A health monitoring system has been made with vital signs check. In this research measurement of heart rate and body temperature using AD8232 ECG’s sensor as measurement instrumentation of electrocardiogram and DS18b20 to check body temperature. Monitoring is done in real time based on IoT (Internet of Things) system which using Thingspeak server. How the device to work is so simply, with send analog signals to microcontroller that are data of body temperature and heart rate in the form of ECG fluctuating waves which is displayed on the serial plotter of Arduino UNO then which will be processed into BPM Value and transmit to thingspeak server. With the result that making possible to person monitors the other person. The device work properly based on testings that have been done with ralat percentage by 1,83% for BPM measurement by ECG’s sensor and 0,636% for measurement of body temperature by DS18b20. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Sumatera Utara | en_US |
dc.subject | AD8232 | en_US |
dc.subject | EKG | en_US |
dc.subject | DS18b20 | en_US |
dc.subject | IoT | en_US |
dc.subject | Temperatur | en_US |
dc.subject | Thingspeak | en_US |
dc.title | Sistem Monitoring Kesehatan dengan Instrumentasi Pengukuran Elektrokardiogram dan Suhu Tubuh Berbasis IOT | en_US |
dc.type | Thesis | en_US |
dc.identifier.nim | NIM160801035 | |
dc.description.pages | 86 Halaman | en_US |
dc.description.type | Skripsi Sarjana | en_US |