    Sistem Kontrol dan Monitoring Kegagalan Suplai Tegangan pada Uninterruptible Power Supply (Ups) Berbasis Iot

    View/Open
    fulltext (3.078Mb)
    Date
    2021
    Author
    Wijaya, Adji Satrya
    Advisor(s)
    Situmorang, Marhaposan
    Metadata
    Show full item record
    Abstract
    Terus bertambahnya peralatan elektronik dan berkembangnya jenis-jenis peralatan elektronik baru membuat konsumsi daya listrik penggunaan peralatan elektronik terus bertambah setiap tahun. Dengan kondisi tersebut harus tersedianya listrik dari sumber pembangkit dengan memastikan sebandingnya kapasitas total pembangkit dengan kebutuhan konsumsi daya. Sarana dan prasarana pada pembangkit tenaga listrik harus tetap terjaga dan dalam kondisi terbaik seperti generator, turbin, transformator, dan beberapa sistem seperti sistem DC harus dalam kinerja yang maksimal. Pada pembangkit listrik, sistem DC memiliki fungsi utama sebagai penyedia sumber DC yang digunakan untuk sistem kontrol pada pembangkit dan juga sebagai tenaga cadangan yang dapat digunakan saat darurat . Sistem DC biasanya menggunakan batrai sebagai tempat menyimpan daya sementara .Untuk mempermudah kerja petugas dalam hal perawatan agar sistem UPS selalu dalam kondisi terbaik sehingga menghindari terjadinya kendala suplay daya pada sistem maka dibuat sebuah sistem kontrol dan monitoring khusus untuk mengendalikan kinerja secara manual maupun mengambil tindakan secara otomatis dan melakukan pemantauan keadaan jarak jauh dengan menampilkannya pada layar komputer. Dalam pembuatan sistem menggunakan beberapa komponen seperti Microkontroller, sensor tegangan , relay, papan PCB, dan beberapa kompnen pendukung seperti kabel dan terminal konektor. Adapun metode dan fungsi kerja komponen tersebut adalah microcontroller sebagai tempat pemrosesan data dari pembacaan sensor tegangan yang dipasang pada titik-titik ukur yang selanjutnya data tersebut dikirimkan ke NodeMCU melalui komunikasi serial antara mikrokontroler dan NodeMCU. Data tersebut selanjutnya di kirimkan ke database thinkspeak melalui jaringan internet sehingga dapat diakses dari mana saja untuk keperluan monitoring maupun kontrol untuk mencegah kendala dalam proses suplay daya. Dalam proses pengiriman data memerlukan jeda selama 5 menit dalam pengiriman data ke database thinkspeak dan akan terus bertambah seiring dengan bertambahnya jumlah data yang masuk ke database tersebut, maka digunakan PLQ DAQ untuk pembanding data per satuan detik pada sistem.
     
    The continuous increase in electronic equipment and the development of new types of electronic equipment make the consumption of electric power using electronic equipment continues to increase every year. Under these conditions, the availability of electricity from generating sources must ensure that the total capacity of the generator is proportional to the needs for power consumption. The facilities and infrastructure at the power plant must be maintained and in the best condition, such as generators, turbines, transformers, and several systems such as the DC system must be in maximum performance. In power plants, the DC system has the main function of providing a DC source that is used for the control system in the generator and also as backup power that can be used in an emergency. DC systems usually use batteries as a place to store temporary power. To facilitate the work of officers in terms of maintenance so that the UPS system is always in the best condition so that it avoids problems with power supply to the system, a special control and monitoring system is created to control performance manually or take action manually. automatically and perform remote state monitoring by displaying it on a computer screen. In making the system, several components are used, such as a microcontroller, voltage sensor, relay, PCB board, and several supporting components such as cables and connector terminals. The method and function of this component is a microcontroller as a place for processing data from voltage sensor readings installed at measuring points which are then sent to NodeMCU via serial communication between the microcontroller and NodeMCU. The data is then sent to thedatabase thinkspeak via the internet network so that it can be accessed from anywhere for monitoring and control purposes to prevent problems in the power supply process. In the process of sending data, it requires a 5 minute pause in sending data to thedatabase thinkspeak and it will continue to increase along with the increase in the amount of data entered into the database, so PLQ-DAQ is used to compare data per unit second on the system.

    URI
    http://repositori.usu.ac.id/handle/123456789/32358
    Collections
    • Undergraduate Theses [1324]

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV