Pengaruh Ketebalan Lapisan Opak dengan Lapisan Dentin Terhadap Kesesuaian Warna Pada Mahkota Keramik-Logam
View/ Open
Date
2015Author
Sinamo, Sopan
Advisor(s)
Z Tamin, Haslinda
Agusnar, Harry
Metadata
Show full item recordAbstract
Color matching of metal-ceramic crown towards natural tooth is a key to
success in the science of aesthetic prosthodontics. Due to metal coping in metalceramic
crown as a result from the laboratory process, a black shadow reflection was
seen and it does not correspond with the color shade guide that has been determined
in clinic, thus aesthetic is less satisfactory. Color determination of metal-ceramic
crown is influenced by three factors includes; the color determination in the clinic,
communication between the dentist and the technician in the laboratory, and the color
matching in the laboratory. Color determination in the clinic is influenced by the of
color determination technique, light sources, metamerism, environmental conditions,
operator, and the patient position. Factors corresponding to the color matching in the
laboratory are condensation techniques, firing cycle, glazing cycle, the type of
porcelain, the comparison between the porcelain powder with a liquid, metal type
and thickness layer of porcelain. The aim of this study was to investigate whether
there is an influence of opaque layer thickness with dentine layer thickness towards
the color matching using shade guide on a metal-ceramic crown.
This research was based on experimental laboratory. The manufacture of 27
metal-ceramic samples were made in Unit UJI Laboratorium Dental Faculty of
Dentistry, USU. Five shade guide that were used as control group is 3M2 Vita 3D
Master (Vita Zahnfabrick, Sackingen, West Germany). Metal-ceramic sample group
were divided into six groups, which consist of opaque layer thickness of 0.2 and 0.3
mm with a dentine layer of 0.5, 0.7 and 1.0 mm. The measurement of L *, a *, b *
values in the sample group and the shade guide was done using the
spectrophotometer UV. Influence of the opaque layer thickness of 0.2 and 0.3 mm
with the dentine layer thickness of 0.5, 0.7, and 1.0 mm towards the color matching
was analyzed using one way ANOVA test. T-test was used to analyse the difference
between the influence of the opaque layer thickness of 0.2 and 0.3 mm with the
dentine layer thickness of 0.5, 0.7 and 1.0 mm towards color matching. Color
matching of each metal-ceramic samples was obtained by calculating the difference
in total color value (ΔE*) in each sample, using the formula: ΔE* = (ΔL* 2 + Δa* 2 +
Δb* 2) ½ The value of ΔL*, Δa*, and Δb* was obtained by calculating the difference
between the average value of L*, a*, b* in the sample group of metal-ceramic with a
mean value of L*, a*, b* shade guide. Comparison of the effects between the opaque
layer thickness of 0.2 and 0.3 mm with a dentine layer thickness of 0.5, 0.7 and 1.0
mm towards color matching were analyzed by using LSD test.
The results showed that there was an influence of the opaque layer thickness
of 0.2 mm for color matching in metal-ceramic crown. There was an influence of an
opaque layer thickness of 0.3 mm towards the dentine layer thickness of 0.5, 0.7 and
1.0 mm for color matching in metal-ceramic crown. There was a difference in the
effect between opaque layer thickness of 0.2 and 0.3 mm with a dentine layer
23
thickness of 0.5, 0.7 and 1.0 mm for color matching in metal-ceramic. There was a
comparison in the effect of opaque layer thickness of 0.2 and 0.3 mm with the
dentine layer thickness of 0.5, 0.7and 1.0 mm for color matching in metal-ceramic
crown. The lowest value of ΔE* was contained in the opaque layer thickness of 0.2
mm with 1.0 mm dentine layer thickness (6.66 ± 1.42).The lowest value of ΔE* was
the most appropriate color with the shade guide. The the most significant value of
ΔE* was statistically contained in the opaque layer thickness of 0.2 mm with 1.0 mm
of dentine layer thickness (p = 0.03)
Opaque layer thickness of 0.2 mm with 1.0 mm dentine layer thickness is
recommended as a guide for manufacturing metal-ceramic crowns to produce a
matched color with the shade guide, in order to obtain a satisfactory aesthetic results
for dentists and patients. Kesesuaian warna mahkota keramik-logam terhadap gigi asli merupakan
kunci keberhasilan estetik dalam ilmu prostodontik. Adanya bayangan hitam yang
dipantulkan oleh koping logam sering terjadi pada mahkota keramik-logam
mengakibatkan warna yang dihasilkan dari proses laboratorium tidak sesuai dengan
warna shade guide yang telah ditentukan di klinik sehingga estetik kurang
memuaskan. Keberhasilan warna pada pembuatan mahkota keramik-logam
dipengaruhi oleh tiga faktor, antara lain: faktor-faktor penentuan warna di klinik,
komunikasi yang baik antara dokter gigi dengan teknisi di laboratorium, dan faktorfaktor
penyesuaian warna di laboratorium. Faktor-faktor penentuan warna di klinik,
termasuk teknik penentuan warna, sumber cahaya, metamerisme, keadaan
lingkungan, operator, dan posisi pasien. Faktor-faktor penyesuaian warna di
laboratorium, termasuk teknik kondensasi, siklus pembakaran, siklus glazing, jenis
porselen, perbandingan antara bubuk porselen dengan cairan, jenis logam dan
ketebalan lapisan porselen. Tujuan penelitian ini adalah untuk mengetahui apakah ada
pengaruh ketebalan lapisan opak dengan lapisan dentin terhadap kesesuaian warna
shade guide pada mahkota keramik-logam.
Jenis penelitian ini adalah eksperimental laboratoris. Pembuatan sampel
keramik-logam berjumlah 27 sampel dilakukan di Unit UJI Laboratorium Dental
FKG USU. Lima shade guide yang digunakan sebagai kelompok kontrol adalah 3M2
Vita 3D Master (Vita Zahnfabrick, Sackingen, West Germany. Kelompok sampel
keramik-logam dibagi atas enam kelompok, yang terdiri dari ketebalan lapisan opak
0,2 dan 0,3 mm dengan lapisan dentin 0,5; 0,7; dan 1,0 mm. Pengukuran nilai L*, a*,
b* pada kelompok sampel dan shade guide dilakukan dengan alat spektrofotometer
UV. Pengaruh ketebalan lapisan opak 0,2 dan 0,3 mm dengan lapisan dentin 0,5; 0,7;
dan 1,0 mm terhadap kesesuaian warna dianalisis dengan uji one-way Anova.
Perbedaan pengaruh antara ketebalan lapisan opak 0,2 dan 0,3 mm dengan lapisan
dentin 0,5; 0,7; 1,0 mm terhadap kesesuaian warna dianalisis dengan uji T.
Kesesuaian warna masing-masing kelompok sampel keramik-logam diperoleh dengan
menghitung perbedaan nilai warna total (ΔE) pada setiap sampel, menggunakan
rumus: ΔE* = (ΔL*2 + Δa*2 + Δb*2)1/2. Nilai ΔL*, Δa*, dan Δb* diperoleh dengan
menghitung selisih antara nilai rerata L*, a*, b* pada kelompok sampel kerangkalogam
dengan nilai rerata L*, a*, b* shade guide. Perbandingan pengaruh diantara
ketebalan lapisan opak 0,2 dan 0,3 mm dengan lapisan dentin 0,5; 0,7; 1,0 mm
terhadap kesesuaian warna shade guide di analisis dengan uji LSD.
Hasil penelitian menunjukkan bahwa ada pengaruh ketebalan lapisan opak 0,2
mm dengan lapisan dentin 0,5; 0,7; 1,0 mm terhadap kesesuaian warna pada mahkota
keramik-logam. Ada pengaruh ketebalan lapisan opak 0,3 mm dengan lapisan dentin
0,5; 0,7; dan 1,0 mm terhadap kesesuaian warna pada mahkota keramik-logam. Ada
perbedaan pengaruh antara ketebalan lapisan opak 0,2 dan 0,3 mm dengan lapisan
dentin 0,5; 0,7; dan 1,0 mm terhadap kesesuaian warna pada keramik-logam. Ada
21
perbandingan pengaruh ketebalan lapisan opak 0,2 dan 0,3 mm dengan lapisan dentin
0,5; 0,7; dan 1,0 mm terhadap kesesuaian warna pada mahkota keramik-logam. Nilai
rerata ΔE* terendah terdapat pada ketebalan lapisan opak 0,2 mm dengan dentin 1,0
mm (6,66 ±1,42). Nilai ΔE* terendah merupakan nilai warna yang paling sesuai
dengan warna shade guide. Secara statistik memperlihatkan nilai ΔE* yang paling
signifikan terdapat pada ketebalan lapisan opak 0,2 mm dengan lapisan dentin 1,0
mm (p=0,03).
Ketebalan lapisan opak 0,2 mm dengan lapisan dentin 1,0 mm
direkomendasikan sebagai panduan pembuatan mahkota keramik-logam untuk
menghasilkan kesesuaian warna dengan shade guide, sehingga diperoleh hasil estetik
yang memuaskan bagi dokter gigi dan pasien.
Collections
- Master Theses [46]