| dc.description.abstract | Has designed a measuring instrument calibration volume of water with measuring cup using HC - SR04 ultrasonic sensor . The system to be based on a microcontroller as a data processor . Furthermore, the measurement results displayed on an LCD screen .
From the test results it can be concluded that the volume of the tube I error is 73,3 % per cent of the appliance and the second tube volume percent error appliance is 74,4 %. | en_US |
| dc.description.abstract | Telah dirancang suatu alat ukur volume air dengan kalibrasi gelas ukur menggunakan sensor ultrasonic HC-SR04. Sistem tersebut berbasis pada mikrokontroler sebagai pengolah data. Selanjutnya hasil pengukuran ditampilkan pada sebuah layar LCD.
Dari hasil pengujian dapat disimpulkan bahwa volume tabung I kesalahan persen alatnya adalah 73,3 % dan volume tabung II kesalahan persen alatnya adalah 74,4 %. | en_US |
| dc.language.iso | id | en_US |
| dc.subject | HC - SR04 Ultrasonic Sensor | en_US |
| dc.subject | Volume Tube Calibration cylinder | en_US |
| dc.subject | LCD ( Liquid Crystal Display ) | en_US |
| dc.subject | LCD ( Liquid Crystal Display ) | en_US |
| dc.title | Perancangan Alat Ukur Volume Air menggunakan Sensor UltrasonikHC-SR04 | en_US |
| dc.type | Thesis | en_US |
| dc.identifier.nim | NIM122411072 | en_US |
| dc.identifier.submitter | Akhmad Danil | |
| dc.description.type | Kertas Karya Diploma | en_US |