Show simple item record

dc.contributor.advisorHanafie, Achsanuddin
dc.contributor.advisorWijaya, Dadik Wahyu
dc.contributor.authorBangun, Primta
dc.date.accessioned2022-10-24T04:30:13Z
dc.date.available2022-10-24T04:30:13Z
dc.date.issued2016
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/50855
dc.description.abstractBackground : One of the common causes of bacterial infection derived from the use of equipment, incorrect aseptic technique, or antiseptic solutions. The common antiseptic that is used in central venous catheterization is Chlorhexidine 2% and Povidone Iodine 10%. The effectivity of these antiseptic are different in some studies, which has effect on the CRBSI incidence. Objective : To achieve optimal antiseptic in order to reduce the bacterial density and CRBSI incidence Method : This single blinded Analitic Cohort Study Design included 40 ICU patients RSUP HAM which is divided into two groups; group A with Chlorhexidine 2% -Alcohol 70% and group B with Povidone iodine 10% -Alcohol 70%. The bacteries were swabed using a sterile sticks, then divided it into pre test - post test control group. The t-test analysis was used to compare the bacterial density from each group before and after antiseptic administration. Whereas, to compare the decline the bacterial density (antiseptic response), we used t-pair test analysis. Confidence interval: 95% with p value< 0,05 is considered statistically significant. Results : The decrease in the bacterial density occurred in group A, mean 99,87% (SB=0,28%), while in group B, mean 98,83% (SB=l,86%) with p value< 0,001. Conclusions : Chlorhexidine 2% - Alcohol 70% is more effective to reduce bacterial density and CRBSI incidence, compare to Povidone Iodine 10% - Alcohol 70%.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectChlorhexidineen_US
dc.subjectPovidone Iodineen_US
dc.subjectBacterial Densityen_US
dc.subjectAntiseptic Solutionsen_US
dc.titlePerbandingan Chlorhexidine 2%-Alkohol 70% dengan Povidone Iodine 10% -Alkohol 70% terhadap Penurunan Kepadatan Kuman dalam Mengurangi Resiko CRBSI pada Pemasangan Kateter Vena Sentral di RSUP Haji Adam Malik Medanen_US
dc.typeThesisen_US
dc.identifier.nimNIM117114002
dc.identifier.nidnNIDN0026085204
dc.identifier.kodeprodiKODEPRODI11706#Anestesiologi dan Reanimasi
dc.description.pages92 Halamanen_US
dc.description.typeTesis Magisteren_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record