| dc.description.abstract | The objective of this study are 1) to know the relation of using high-speed
dental drill with the hearing trouble to dentist; 2) to note the relation of length daily
exposed with the hearing trouble on dentist; 3) to know the relation of the age with
the hearing trouble on dentist.
This study adopted a descriptive design using a cross-sectional method. The
data collecting taken by conducting a measure to the hearing trouble by an
audiometric tools and found a noise level intensity on the work place where the
dentist always be dealing with the high speed bur.
For the data analysis, it was processed under SPSS program, there applied a
uni-variety and bi-variety in this case analyzed vvith a Chi-Square method in
practically to study either found a relation between using a high speed bur or not
with the hearing trouble to the dentists. The location of study held on city X covering
7 Puskesmas, 1 City hospital and 1 private hospital and still on a clinic for practicing.
The result of study showed that : I) Noise level high-speed bur on city X
having a noise intensity rate exceeding a threshold rate (NAB); 2) a significance
result on its audiometric test between the length of expose with the hearing trouble on
daily expose hours spent exceeding 4 hours each day; 3) no significance relation
between the age with the hearing trouble; 4) no significance relation between the
noise level I intensity with the hearing trouble.
The efforts for controlling the noises recommended are as the following: I)
protection by wear standard hearing Protection Tool - Hearing Protective Device set
by dentist is in order to eliminate Noise Hazard; 2) self protection by having pause
time of 15 - 30 seconds per patient; whereby the expose time of drill 14-45 minutes;
3) working shift on Puskesmas; 4) existing socialization NIHL and uses Hearing
Protective Device by the PDGI | en_US |
| dc.language.iso | id | en_US |
| dc.publisher | Universitas Sumatera Utara | en_US |
| dc.subject | High Speed Bur | en_US |
| dc.subject | Noisy | en_US |
| dc.subject | Intensity | en_US |
| dc.subject | NIHL | en_US |
| dc.subject | Daily Expose Time | en_US |
| dc.title | Hubungan Pemakaian High-Speed Bur Gigi dengan Gangguan Pendengaran pada Dokter Gigi di Kota X | en_US |
| dc.type | Thesis | en_US |
| dc.identifier.nim | NIM057010006 | |
| dc.identifier.nidn | NIDN0031084802 | |
| dc.identifier.nidn | NIDN0024126402 | |
| dc.identifier.nidn | NIDN0017076005 | |
| dc.identifier.kodeprodi | KODEPRODI13101#Ilmu Kesehatan Masyarakat | |
| dc.description.pages | 119 Halaman | en_US |
| dc.description.type | Tesis Magister | en_US |