Pengaruh Tekanan dan Waktu Perebusan terhadap Kehilangan Minyak (Losses) pada Air Kondensat di Stasiun Sterilizer dengan Sistem Tiga Puncak (Triple Peak) di Pabrik Kelapa Sawit Ptpn Iv (Persero) Pulu Raja
View/ Open
Date
2012Author
Putri, Astia Budi Perdana
Advisor(s)
Surbakti, Darwis
Metadata
Show full item recordAbstract
Losses of oil on the boiling station are as prevalent as experienced by the Palm Oil
mills in the processing. Losses are conditions that must be minimized because it cause
loss to the company.
Levels of losses in boiling water station can be analyzed through a sample of
condensate water. Created variations in pressure and boiling time for each of the
condensate water samples taken. Of each different treatment would be obtained in
different levels of losses. The optimum conditions of boiling on the sterilizer PTPN IV
Pulu Raja was at a pressure of 2.76 kg/cm2 with a 90-minute boiling time and
temperature was 135oC and a boiling system of three-peak pattern (triple peak) which
generated losses in the condensate water by 0.74%.