dc.description.abstractIt has been observed in the PT. Toba Pulp Lestari Tbk on the effect of 98% sulfuric acid on the flow rate of the drying process chlorine, Chlorine is corrosive if it contains water, therefore it is important to drying up of the chlorine to prevent corrosive of the equipment. In accordance, with the observations that have been made to the chlorine 90.62% it was needed 98% sulfuric acid with flow rate of 2.2347 tons / hour resulting chlorine 99%. The smaller the concentration of chlorine that enters drying tower the 98% sulfuric acid was needed higher. When the chlorine products was larger, the flow rate of 98% sulfuric acid must be enlarged to find out standard chlorine concentrationen_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.titlePengaruh Laju Alir H2so4 98% terhadap Proses Pengeringan Gas Khlorin (Cl2) di Unit Drying Tower pada Proses Chlorine Treatment di Chemical Plant PT. Toba Pulp Lestari, Tbk – Porseaen_US
dc.typeThesisen_US
dc.identifier.nimNIM112401063
dc.identifier.nidnNIDN0030065102
dc.identifier.kodeprodiKODEPRODI47401#Kimia
dc.description.pages37 Halamanen_US
dc.description.typeKertas Karya Diplomaen_US