dc.description.abstract | It has been designed and analyzed utilizing the tool incubator with Peltier element
hot side. This study uses a Peltier TEC1-12706. This study analyzes and works by
utilizing the Peltier Seebeck effect, which is currently electrified peltier cooler
absorption occurs on one side and the release of heat on the other side. Hot side
incubator is used to heat the room, where the temperature detected by sensor
LM35. Temperature values read on the LCD indicator. Expenses are heated in the
form of egg volume varied from 100 grams, 150 grams, 200 grams, 250 grams,
300 grams, 400 grams, 450 grams, 500 grams, 550 grams, 650 grams. The time
needed to reach the temperature of each 0.5 minutes, 0.72 minutes, 2.64 minutes,
5 minutes, 11.16 minutes, 17.92 minutes, 23.76 minutes, 35 minutes, 43.56
minutes, 64.22 minutes. From the data obtained can be concluded peltier heating
time required is directly proportional to the load, where the greater the burden that
is heated the more time it takes to reach maximum temperature. When the load of
100 liters to reach 25 ° C takes 0.5 minutes, when the load of 650 grams to
achieve a maximum temperature of 38 ° C takes 64.22 minutes. | en_US |