dc.description.abstract | Alat penukar kalor (heat exchanger) pipa konsentris tiga saluran
merupakan pengembangan atau perbaikan alat penukar kalor konsentris
dua saluran. Penelitian ini dilakukan untuk mengetahui temperature
keluaran masing-masing saluran, serta membandingkan hasil perhitungan
secara teori menggunakan pemodelan matematika terhadap hasil
eksperimen yang dilakukan dilapangan. Sehingga didapat perbedaan nilai
antara hasil eksperimen terhadap hasil perhitungan teori. Pada penelitian
ini memiliki 3 variasi data suhu yaitu sebesar 50°C, 55°C, dan 60°C
dengan dua aliran yaitu CounterFlow dan PararellFLow dan debit 2,5
l/menit, sedangkan fluida dingin dengan 25°C debit 1,5 l/menit. Dari
analisa diatas dapat disimpulkan temperature fluida panas keluar dari APK
pada eksperimen cenderung lebih tinggi dibandingkan dengan temperatur
fluida panas keluar dari APK pada perhitungan teoritis metode pemodelan
matematika. Sementara itu temperatur fluida dingin dingin keluar dari
APK pada eksperimental cenderung lebih rendah dibandingkan dengan
temperatur fluida dingin keluar dari APK pada perhitungan teoritis metode
pemodelan matematika. | en_US |
dc.description.abstract | A three-channel concentric pipes heat exchanger is a development or
improvement of a two-channel concentric heat exchange apparatus. This study
was conducted to determine the output temperature of each channel, and compare
the results of theoretical calculations using mathematical modeling of
experimental results conducted in the field. So that obtained difference of value
between result of experiment to result of theory calculation. In this study have 3
variations of temperature data that is 50 ° C, 55 ° C, and 60 ° C with two
streams namely CounterFlow and PararellFLow and discharge 2.5 l/minute, while
cold fluid with 25 ° C discharge 1.5 l/minute. From the above analysis it can
be concluded that the temperature of the hot fluid coming out of the APK in the
experiment tends to be higher than the temperature of the hot fluid coming out of
the APK on theoretical calculations of mathematical modeling methods.
Meanwhile, the cold cold fluid temperature coming out of the APK in
experimental tends to be lower than the temperature of the cold fluid coming out
of the APK on theoretical calculations of mathematical modeling methods. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Sumatera Utara | en_US |
dc.subject | Heat Exchanger | en_US |
dc.subject | Double Concentric Pipe | en_US |
dc.subject | Triple Concentric Pipe | en_US |
dc.title | Analisa Alat Penukar Kalor Tiga Lapis Tabung Konsentris Menggunakan Pemodelan Matematika | en_US |
dc.type | Thesis | en_US |
dc.identifier.nim | NIM130401114 | en_US |
dc.identifier.submitter | Nurhusnah Siregar | |
dc.description.type | Skripsi Sarjana | en_US |