Show simple item record

dc.contributor.advisorHanafie, Achsanuddin
dc.contributor.advisorHamdi, Tasrif
dc.contributor.authorRicardo, Dion
dc.date.accessioned2023-01-30T03:08:55Z
dc.date.available2023-01-30T03:08:55Z
dc.date.issued2022
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/81108
dc.description.abstractIntroduction: Caesarean section (SC) is defined as the birth of a baby through an incision in the abdomen (laparotomy) and uterus (hysterotomy). Spinal anesthesia is the choice for elective SC because it is considered effective and efficient considering its simple technique and ability to provide adequate surgical anesthesia, easy administration, faster onset, and safety. Spinal anesthesia also provides early skin to skin contact which increases maternal satisfaction though hypotension risk is higher compared to epidural anesthesia which countered by sympathomimetic vasopressors administration. Objective: To compare the administration of 10 IU oxytocin diluted in 10 cc of 0.9% NaCl for 15 seconds with 60 seconds on hemodynamics in sectio caesarean patients under spinal anesthesia. Methods: This study used an RCT (Randomized Clinical Trial) design with double blind, meaning that neither the research subjects nor the observers aware about the treatment or intervention given. The study sample was patients who underwent Sectio Caesaria at Haji Adam Malik General Hospital Medan, and the Universitas Sumatera Utara Hospital which fulfilled the inclusion and exclusion criteria. Results: It was found that there was not a significant difference in MAP values between the 15-second and 60-second bolus groups with p-values for the 1st, 3rd, 5th, and 10th minutes respectively 0,804, 0,692, 0,568, 0,216, 0,754, dan 0,390. In addition, it is known that there was a significant difference in pulse values between the 15-second and 60-second bolus groups at 1, 3, 5, 10 and 15 minutes, with the results of the p-value before, 1, 3, 5, 10, and 15 minutes. are 0.509, 0.464, 0.805, 0.055, 0.475 and 0.857 respectively. In this study, no side effects were found in either group between 15 second and 60 second boluses. Conclusion: There were not significant hemodynamic changes in both test groups (15 second and 60 second boluses), at 1, 3, 5, 10 and 15 minutes.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectCaesarean sectionen_US
dc.subjectHemodynamicsen_US
dc.subject15 secondsen_US
dc.subject60 secondsen_US
dc.titlePerbandingan Pemberian Oksitosin 10 IU Intravena Pengenceran 10 Cc NaCl 0,9% Bolus selama 15 Detik dengan 60 Detik terhadap Hemodinamik pada Pasien Sectio Caesaria dengan Anestesi Spinal di Rumah Sakit Umum Pusat Haji Adam Malik Medanen_US
dc.typeThesisen_US
dc.identifier.nimNIM187114019
dc.identifier.nidnNIDN0026085204
dc.identifier.nidnNIDN0025058504
dc.identifier.kodeprodiKODEPRODI11103#Ilmu Kedokteran Klinis
dc.description.pages76 Halamanen_US
dc.description.typeTesis Magisteren_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record