dc.description.abstractUtilization ionizing radiation was contained in Government Regulation of the Republic of Indonesia No. 33 of 2007 concerning the safety and security provisions for the used of ionizing radiation refers to the provisions of the International Atomic Energy Agency (IAEA) and those issued by the International Commission on Radiological Protection. Government regulations regulated radiation safety for workers, the public, the environment as well as the safety of radioactive sources and inspectors in the use of nuclear power. The use of ionizing radiation sources for the purpose of radiation protection was required to measure the ionizing radiation. Radiation measuring instruments must be calibrated against reference measuring instruments traceable to the National Standard Laboratory in accordance with the amount of radiation being measured. One of the health instruments that needs to be calibrated was a pen dosimeter, it was a personal radiation protection measuring instrument used by radiation workers in radiology installations in hospitals. Radiation Measuring Instrument Calibration (AUR) has been carried out at the Health Facilities Security Agency, Medan. The calibration method used was the substitution method, the detector was irradiated in the gamma radiation field Cs – 137. Determination of calibration factor values and uncertainty to digital dosimeters used the Cesium standard – 137. In calibration, there was a standard deviation of obtained of 2,022% and a calibration factor of 1,02 μGy. An obtained measured dose and the dose read with a dose rate of 71.878114 μGy and an uncertainty value of 9.65% μGy. So that the digital dosimeter pen was good to use because it had a calibration factor value according to predetermined standards.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectCalibration Factoren_US
dc.subjectIonizing Radiationen_US
dc.subjectPen Dosimeteren_US
dc.subjectUncertaintyen_US
dc.titlePemanfaatan Cesium – 137 Sebagai Sumber Standar Kalibrasi pada Alat Ukur Radiasi Pen Dosimeter Type DMC 3000 Sn. 01A0734Cen_US
dc.typeThesisen_US
dc.identifier.nimNIDN0002097904
dc.identifier.nimNIM180801025
dc.identifier.kodeprodiKODEPRODI45101#FISIKA
dc.description.pages91 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record