Show simple item record

dc.contributor.advisorSiregar, Galih Ari Wirawan
dc.contributor.authorSofina, Dhea
dc.date.accessioned2023-08-16T01:55:04Z
dc.date.available2023-08-16T01:55:04Z
dc.date.issued2023
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/86594
dc.description.abstractAir pollution from the livestock industry is caused by livestock manure. Rabbit urine contains the compound ammonium hydroxide. Excessive levels of ammonium hydroxide or ammonia are indicators that can be used as an indication of air pollution. Zeolite has characteristics as an absorbent of ammonia to a material. The use of zeolite in rabbit urine will affect ammonia levels. The research was carried out in September 2022 – April 2023 in research rabbit cages and the Laboratory for Environmental Health Engineering and Disease Control (BTKLPP). This study used an experimental method with a completely randomized design (CRD) consisting of 4 treatments for zeolite content in grams (gr): P1 (20 gr), P2 (30 gr), P3 (40 gr), P4 (50 gr) with 5 replicates. Testing in this study used detectable ammonia levelsrealtime (24 hours) by the MQ-135 sensor, microcontroler NodeMCU ESP8266, relay and DC water pumps that use electricity fromsolar cell in the rabbit study cage compared to the ammonia levels of the urine of the rabbits tested using ammonia analysis using the spectrophotometric method at the BTKLPP Laboratory. The results showed the use of zeolite with different levels in sensor equipment andmicrocontroler did not have a significant effect (P>0.05) on ammonia levels. Analysis of ammonia in rabbit urine had a significant effect (P<0.05) on rabbits aged 19 weeks and had a very significant effect (P<0.01) on ammonia levels in rabbits aged 22 weeks. The use of 30 gr of zeolite can reduce ammonia levels compared to more than 30 gr of zeolite. The use of this equipment is more effective in reducing ammonia levels compared to ammonia analysis using the spectrophotometric method. This is because the tool detects ammonia levels automaticallyrealtime, while ammonia analysis takes 1 week to collect rabbit urine.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectammoniaen_US
dc.subjectMQ-135en_US
dc.subjectNodeMCU ESP8266en_US
dc.subjectrabbiten_US
dc.subjectzeoliteen_US
dc.subjectSDGsen_US
dc.titlePemanfaatan Zeolit Sebagai Absorben terhadap Kadar Amonia Urin Kelincien_US
dc.typeThesisen_US
dc.identifier.nimNIM180306018
dc.identifier.nidnNIDN0103018904
dc.identifier.kodeprodiKODEPRODI54231#Peternakan
dc.description.pages59 Halamanen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record