Penentuan Kadar Amonia Nitrogen pada Air Reservoir dengan Metode Nessler pada Instalasi Pengolahan Air Minum PDAM Tirtanadi Sisingamangaraja
View/ Open
Date
2023Author
Ginting, Valentin Sugffi Boru
Advisor(s)
Hardiyanti, Rini
Metadata
Show full item recordAbstract
Determination of amonia nitrogen levels i11 reservoir water usi11g the
nessler method at the drinking water treatment plant of PDAM Tirtanadi
Sisingamagaraja has been carried out. Examination of Ammo11ia Nitroge11 levels
was carried out using the nessler method using a spectriphotometry DR-3900 with
the addition of 3 drops of Mineral Stabilizer,3 drops of Polyvinyl Alcohol
Dispersing Agen, and 1 mL of Nessler reagent. From the analysis of the
determination of Ammonia Nitrogen levels that have been carried out i11 the Water
Reservoir, Ammonia Nitrogen levels of 0.07 Mg/L were obtained. Based 011 the
data obtained, the levels of ammonia nitrogen in the reservoir water have met the
water quality standards by the Minister of Health of the Republic of Indonesia
No.492/MENKESIPERIJV/2010.