Penentuan Kadar Fluorida dan Kekeruhan pada Air Bersih di Wilayah Berdikari

Date
2023Author
Sinaga, Santa Ulina
Advisor(s)
Muthawali, Dede Ibrahim
Metadata
Show full item recordAbstract
Analysis of the determination of fluoride content and turbidity in
clean water test samples at Berdikari using the colorimetric method with a
spectrophotometer aims to determine fluoride levels and with the turbidimeter
method aims to determine the turbidity level in clean water and compares it with
the quality standards set by the Regulation of the Minister of Health of the
Republic of Indonesia No. 32 of 2017. The results of the analysis carried out
showed that fluoride levels in clean water still met the quality standard limits,
namely 1.12 mg/l in test sample number 006, 1.05 mg/l in test sample number
007, 1.23 mg/l on test sample number 008. The results of the turbidity analysis
of the clean water test sample still met the quality standard limits, namely 1.26
NTU on test sample number 006, 1.12 NTU on test sample number 007, 1.17 on
test sample number 008.