    Kinerja Manajemen Pemeliharaan Bangunan Gedung Rumah Sakit Universitas Sumatera Utara

    Thumbnail
    View/Open
    Cover.pdf (907.5Kb)
    Fulltext (3.927Mb)
    Date
    2022
    Author
    Harahap, Adji Perdana
    Advisor(s)
    Syahrizal
    Syafridon, Gea Geby Aurora
    Metadata
    Show full item record
    Abstract
    Building maintenance is necessary in maintaining the building according to its function and providing comfort for the users of the building. According to the regulation of the minister of public works number 24/PRT/M/2008, there are six components of building maintenance, namely architectural, structural, mechanical, electrical, outdoor space and housekeeping components. The University of North Sumatra Hospital is a hospital that was built in 2012, thus the building has reached 10 years of age. This research was conducted to find out what building maintenance is carried out by the management of the University of North Sumatra hospital to maintain the function and feasibility of the building. The research method was to distribute questionnaires to patients and carers using a modified Likert scale with points 1 (strongly disagree) and 4 (strongly agree). The statistical test used is the Pearson Product Moment validity test, the Alpha Cronbach reliability test. The results showed that the North Sumatra University hospital used the breakdown and corrective maintenance method to carry out building maintenance. While the results of user assessment research were obtained, for building cleanliness the lowest rating interval was 3.00 for ceiling cleanliness, and the highest was 3.29 for toilet cleanliness. For the condition of the building the lowest rating is 2.94 for the condition of the walls, and the highest is 3.51 for the condition of the door. The color of the building gets a score of 2.97, the smell inside the building gets a score of 3.43, the temperature inside the building gets a score of 3.20, and the lighting in the room gets a score of 3.29.
    URI
    https://repositori.usu.ac.id/handle/123456789/91067
    Collections
    • Undergraduate Theses [1607]

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV