• Login
    View Item 
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Undergraduate Theses
    • View Item
    •   USU-IR Home
    • Faculty of Engineering
    • Department of Civil Engineering
    • Undergraduate Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Analisis Tulangan Secant Pile Akibat Tekanan Lateral Tanah (Studi Kasus: Proyek Underpass H.M. Yamin)

    Thumbnail
    View/Open
    Cover.pdf (1.371Mb)
    Fulltext (2.316Mb)
    Date
    2024
    Author
    Prananda, Bayu
    Advisor(s)
    Tarigan, Johannes
    Metadata
    Show full item record
    Abstract
    Medan City in Indonesia has a large and dense population. As a result, there is an increase in the number of vehicles that is not proportional to the available road capacity. In particular, provincial roads that are the main route for logistics delivery to various regions in North Sumatra often experience congestion due to high vehicle volumes and many road intersections. One of the roads affected by congestion is the Jl. H.M. Yamin - Jl. Jawa intersection. Therefore, it is planned to build an underpass on the road as a solution to overcome the congestion problem. In planning the construction of the underpass on H.M. Yamin road - Jl. Jawa intersection, it is planned that the retaining wall used is Secant Pile. In Secant Pile planning, reinforcement planning is very important to ensure the strength of the retaining wall. Therefore, this research aims to evaluate the strength and safety of the retaining wall constructed with Secant Pile, as well as determine the optimal reinforcement to be used in the construction. The results of the analytical calculation of Secant Pile using the empirical formula obtained a transverse force of 126,9 kN and a bending moment of 575,1 kNm. The results are not much different from the results of the analysis with Midas Software, namely the transverse force of 125,4 kN and bending moment of 482,6 kNm. In the reinforcement calculation, the main reinforcement is planned with a diameter of 22 and a diameter of 12 shear reinforcement
    URI
    https://repositori.usu.ac.id/handle/123456789/91674
    Collections
    • Undergraduate Theses [1577]

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of USU-IRCommunities & CollectionsBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit DateThis CollectionBy Issue DateTitlesAuthorsAdvisorsKeywordsTypesBy Submit Date

    My Account

    LoginRegister

    Repositori Institusi Universitas Sumatera Utara - 2025

    Universitas Sumatera Utara

    Perpustakaan

    Resource Guide

    Katalog Perpustakaan

    Journal Elektronik Berlangganan

    Buku Elektronik Berlangganan

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV