dc.description.abstractResearch has been carried out on the measurement of radiation exposure rate and effectiveness of radiation shielding in the CT - Scan room using a Babyline Surveymeter. It aims to determine the radiation exposure rate generated from the CT - Scan equipment and to find out the factors that affect the radiation exposure rate and also to determine the effectiveness of radiation shielding in Dr. Pirngadi General Hospital Medan. Measurement of the rate of radiation exposure is carried out by survey, measurement and documentation methods. Radiation exposure rate measurements were carried out in the operator room, machine room, entrance of operator room, corridor, and SIRS (Hospital Information System) room. Measurement of the exposure rate is measured when exposure passed through radiation shielding while measurement of effectiveness is measured when before and after passing through radiation shielding. The radiation exposure in the operator room is 0.00378 mSv/year; in the machine room is 0.002592 mSv/year; at the entrance of the operator room is 0.00378 mSv/year; in the corridor is 0.004428 mSv/year; in the SIRS (Hospital Information System) room is 0.000864 mSv/year. The results showed that the radiation exposure rate in the CT – Scan room at Dr. Pirngadi General Hospital Medan was below the Dose Limit Value of BAPETEN regulation No. 8 of 2011. The effectiveness measurement in the operator room is 95,89%; in the machine room is 75%; at the entrance of the operator room is 98,59%; in the corridor is 67,77%; and in the SIRS room is 94,12%.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectCT – Scanen_US
dc.subjectShielding Effectivenessen_US
dc.subjectExposure Rateen_US
dc.subjectRadiation Shieldingen_US
dc.subjectSDGsen_US
dc.titlePengukuran Laju Paparan Radiasi dan Efektivitas Perisai Radiasi pada Ruang CT-Scan di RSUD. Dr. Pirngadi Kota Medanen_US
dc.title.alternativeMeasurement of Radiation Exposure Rate and Effectiveness of Radiation Shielding in The CT-Scan Room at Dr. Pirngadi General Hospital Medanen_US
dc.typeThesisen_US
dc.identifier.nimNIM190801006
dc.identifier.nidnNIDN0002097904
dc.identifier.kodeprodiKODEPRODI45201#Fisika
dc.description.pages57 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record