Show simple item record

dc.contributor.advisorHusin, Amir
dc.contributor.authorPutri, Adinda Azzahra
dc.date.accessioned2024-08-14T07:22:35Z
dc.date.available2024-08-14T07:22:35Z
dc.date.issued2024
dc.identifier.urihttps://repositori.usu.ac.id/handle/123456789/95428
dc.description.abstractThe problem of liquid waste has always been an important issue because of its characteristics which can cause environmental pollution, one of which is nitrate. One technology for removing nitrate levels in liquid waste is electrocoagulation. In this study, nitrate removal was carried out using a continuous reactor electrocoagula tion method using iron (Fe) electrodes with variations in electrode distance and flow rate. The results of the study showed that the highest nitrate removal efficiency obtained was 86.26% in the treatment of 2 cm electrode distance and flow rate. 100 mL/mi nute.en_US
dc.language.isoiden_US
dc.publisherUniversitas Sumatera Utaraen_US
dc.subjectElectrocoagulationen_US
dc.subjectContinuous Reactoren_US
dc.subjectNitrateen_US
dc.titleStudi Pengaruh Variasi Jarak Elektroda dan Laju Alir terhadap Kinerja Reaktor Elektrokoagulasi Kontinu untuk Penyisihan Nitraten_US
dc.title.alternativeStudy The Effect of Variation of Electrode Distance and Flow Rate on The Performance of Continuous Electrocoagulation Reactors for Nitrate Removalen_US
dc.typeThesisen_US
dc.identifier.nimNIM190407025
dc.identifier.nidnNIDN0015026904
dc.identifier.kodeprodiKODEPRODI25201#Teknik Lingkungan
dc.description.pages59 Pagesen_US
dc.description.typeSkripsi Sarjanaen_US