dc.contributor.advisor | Pasaribu, Albert | |
dc.contributor.author | Simbolon, Zann Akbar Pratama | |
dc.date.accessioned | 2024-08-26T08:30:04Z | |
dc.date.available | 2024-08-26T08:30:04Z | |
dc.date.issued | 2024 | |
dc.identifier.uri | https://repositori.usu.ac.id/handle/123456789/96128 | |
dc.description.abstract | Analysis of Chemical Oxygen Demand (COD), Total Dissolved Solids (TDS),
and Total Suspended Solids (TSS) levels in Wastewater at UPT has been carried out.
North Sumatra Provincial Health Laboratory. The purpose of this analysis is to
determine the levels of Chemical Oxygen Demand (COD), Total Dissolved Solids
(TDS), and Total Suspended Solids (TSS) analyzed at the UPT. North Sumatra
Provincial Health Laboratory. Data is taken from a variety of different wastewater
sources. Analysis of Chemical Oxygen Demand (COD) levels using the Titrimetry
method and Analysis of Total Dissolved (TDS) and Total Suspended Solids (TSS) using
the Gravimetry method. The results showed significant variations in the
concentrations of these three parameters, reflecting the complexity of the waste
composition. From the results of the analysis, it was found that the level of Chemical
Oxygen Demand (COD) in wastewater was 80 mg/L; 52.8 mg/L; 64 mg/L; 94.4 mg/L;
78.4 mg/L; 91.2 mg/L. The analysis results for Total Dissolved Solids (TDS) levels
were 134 mg/L; 172 mg/L; 156 mg/L; 226 mg/L; 136 mg/L; 239 mg/L; 170 mg/L; 208
mg/L; 165 mg/L; 258 mg/L; 156 mg/L. And the analysis results for Total Suspended
Solids (TSS) levels were 17 mg/L; 29 mg/L; 29 mg/L; 26 mg/L; 27 mg/L; 19 mg/L; 18
mg/L; 24 mg/L; 17 mg/L; 24 mg/L; 21 mg/L. Based on the data from the analysis
results, it can be concluded that the levels of Chemical Oxygen Demand (COD), Total
Dissolved Solids (TDS), and Total Suspended Solids (TSS) in waste water are in
accordance with the water quality standards issued by Regulation of the Minister of
Environment and Forestry of the Republic of Indonesia No. .68 of 2016 concerning
Waste Water Quality Standards and Regulation of the Minister of Environment and
Forestry of the Republic of Indonesia No. 5 of 2014 concerning Waste Water Quality
Standards. | en_US |
dc.language.iso | id | en_US |
dc.publisher | Universitas Sumatera Utara | en_US |
dc.subject | Chemical Oxygen Demand (COD) | en_US |
dc.subject | Total Dissolved Solids (TDS) | en_US |
dc.subject | Total Suspended Solids (TSS) | en_US |
dc.subject | SDGs | en_US |
dc.title | Analisis Chemical Oxygen Demand (COD), Total Dissolved Solids (TDS), dan Total Suspended Solids (TSS) dalam Air Limbah di UPT. Laboratorium Kesehatan Provinsi Sumatera Utara | en_US |
dc.title.alternative | Analysis of Chemical Oxygen Demand (COD), Total Dissolved Solids (TDS), and Total Suspended Solids (TSS) in Waste Water at UPT. Health Laboratory North Sumatra Province | en_US |
dc.type | Thesis | en_US |
dc.identifier.nim | NIM212401008 | |
dc.identifier.nidn | NIDN0010086402 | |
dc.identifier.kodeprodi | KODEPRODI47401#Kimia | |
dc.description.pages | 61 Pages | en_US |
dc.description.type | Kertas Karya Diploma | en_US |