dc.description.abstractChitosan/Cerium Oxide (CeO2) modified copper electrode with a simple and sensitive has been successfully carried out using a cyclic voltammetric method to detect tetracycline antibiotic. The effect of the addition of cerium oxide on the chitosan has been shown to improve the sensing properties of the chitosan electrodes. Chitosan/CeO2 was fabricated using the electrodeposition method at a volume ratio of 1:1 in the form of a 1.5% chitosan solution and various CeO2 concentrations of 0.005, 0.0075, 0.001, 0.0125 and 0.015g. The sensing properties of the chitosan/CeO2 electrode were tested against tetracycline antibiotics with concentrations of 0.1, 0.5, 1, 1.5 and 2 ppm. The characteristics of the chitosan/CeO2 electrode were analyzed using the Scanning Electron Microscopy (SEM) and Fourier Transform Infra-Red (FT-IR) methods. The measurement parameters in this study are low E(V) = -1, high E(V) = +1, scan rate (mV/second) = 75, these parameters are used until the end of the test for analyzing tetracycline antibiotics using the cyclic voltammetry method. The results of the test produce the maximum output voltage of 0.0075g chitosan/CeO2 at a potential of 0.00328 V, a high performance chitosan/CeO2 based electrode used to detect variations in the concentration of tetracycline antibiotics. A tetracycline antibiotic concentration of 0.0075g produces the highest peak oxidation current and potential namely 7.05392 A and 0.992 V. The detection limit (LOD) and quantity limit (LOQ) for detecting tetracycline antibiotics are 0,5533 μM dan 1,8447 μM. The results of this research show that the modified chitosan/CeO2 electrode is able to detect tetracycline antibiotics with the lowest levels and good sensitivity so that it can be applied as a basic sensor material for detecting tetracycline antibioticsen_US
dc.language.isoiden_US
dc.subjectTetracycline Antibioticen_US
dc.subjectCyclic Voltammetryen_US
dc.subjectChitosanen_US
dc.subjectCerium Oxide (CeO2)en_US
dc.subjectElectrodeen_US
dc.subjectSDGsen_US
dc.titleSensitivitas Elektroda Tembaga Termodifikasi Kitosan/Serium Oksida (CeO2) dalam Mendeteksi Konsentrasi Antibiotik Tetrasiklin dengan Siklik Voltammetrien_US
dc.title.alternativeSensitivity of Chitosan/Cerium Oxide (CeO2) Modified Copper Electrode in Detecting Concentrations of Tetracycline Antibiotics with Cyclic Voltammetryen_US
dc.typeThesisen_US
dc.identifier.nimNIM200822015
dc.identifier.nidnNIDN0013017908
dc.identifier.kodeprodiKODEPRODI47201#Kimia
dc.description.pages74 Pagesen_US