Analisa Kinerja Kotak Pendingin Termoelektrik Menggunakan CFD
Performance Analysis of Thermoelectric Cooler Boxes Using CFD

Date
2024Author
Bangun, Axel Chapin Hadryan
Advisor(s)
Sitorus, Tulus Burhanuddin
Metadata
Show full item recordAbstract
The need for refrigeration equipment cannot be separated from human life because it
is used to store various objects such as raw materials for food, drinks and medicine.
The refrigerator is one of these cooling devices. However, the large dimensions of the
refrigerator are very difficult to carry everywhere, therefore it is necessary to develop
a cooling device that is environmentally friendly, effective and energy efficient. The
purpose of this research is to find out the temperature that can be achieved from the
cooling box, the air flow rate that occurs in the cooling box, and the performance of
the cooling box. After carrying out the CFD simulation, the lowest temperature that
can be achieved from the thermoelectric cooling box for 8 hours based on the
simulation data is 17,549 °C. In the simulation the air flow rate that occurs in the
thermoelectric cooling box is turbulent flow where the air flow rate is 8,94 m/s where
the air flow velocity is high and the fluid flows in irregular layers or moves randomly,
and the COP value of the thermoelectric cooler box based on simulation data is 0,1129.
Collections